Installation Guide

16
CAUTION: A chimney re may cause ignition of
wall studs or rafters which you thought were a safe
distance from the chimney. If you have a chimney
re, have your chimney inspected by a qualied
person before using again
CAUTION: Do not burn your stove with the ring
door open, this could cause an over ring situation.
Operating Instructions
CHIMNEY MAINTENANCE
Failure to clean and maintain this unit as
indicated can result in poor performance and
safety hazards.
Never perform any inspections, cleaning, or
maintenance on a hot heater.
Do not operate heater with broken glass,
leakage of ue gas may result.
Keep the Chimney and Chimney Connector
clean and in good condition.
FLUE GAS SYSTEM
Creosote Formation and Need for Removal When
wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors
condense in the relatively cool chimney ue of
a slow-burning re. As a result, creosote residue
accumulates on the ue lining. When ignited this
creosote makes an extremely hot re. The chimney
connector and chimney should be inspected at least
once every two months during the heating season
to determine if a creosote buildup has occurred. If
creosote has accumulated it should be removed to
reduce the risk of a chimney re.
Inspection and Removal The chimney connector
and chimney should be inspected at least twice
monthly during the heating season to determine
if a creosote buildup has occurred. If creosote has
accumulated, it should be removed to reduce
the risk of a chimney re. Inspect the system at the
heater connection and at the chimney top. Cooler
surfaces tend to build creosote deposits quicker, so
it is important to check the chimney from the top
as well as from the bottom. The creosote should be
removed with a brush specically designed for the
type of chimney in use. A qualied chimney sweep
can perform this service. It is also recommended that
before each heating season the entire system be
professionally inspected, cleaned and, if necessary,
repaired. To clean the chimney, disconnect the vent
from the heater.
Chimney res burn very hot. If the chimney
connector should glow red, immediately call the re
department, then reduce the re by pouring a large
quantity of coarse salt, baking soda or cool ashes on
top of the re in the rebox.