Instructions

10 USSC
G

VENTTERMINATIONCLEARANCES

A) Minimum4-foot(1.22m)clearancebeloworbesideanydoororwindowthatopens.
B) Minimum1-foot(0.3m)clearanceaboveanydoororwindowthatopens.
C) Minimum3-foot(0.91m)clearancefromanyadjacentbuilding.
D) Minimum7-foot(2.13m)clearancefromanygradewhenadjacenttopublicwalkways.
E) Minimum2-foot(0.61m)clearanceaboveanygrass,plants,orothercombustiblematerials.
F) Minimum3-foot(0.91m)clearancefromanforcedairintakeofanyappliance.
G)Minimum2-foot(0.61m)clearancebelowevesoroverhang.
H) Minimum1-foot(0.3m)clearancehorizontallyfromcombustiblewall.
I) Mustbeaminimumof3foot(0.91m)abovetheroofand2foot(0.61m)abovethehighestpointortheroofwithin
10feet(3.05m).