Instructions

USSC 9




Thefollowinginstallationguidelinesmustbefollowedtoensureconformitywithboththesafetylistingofthisstoveand
tolocalbuildingcodes.Donotusemakeshiftmethodsorcompromiseintheinstallation.
Thisunitisequippedwithanegativedraftsystemthatpullsairthroughtheburnpotand
pushestheexhaustoutofthedwelling.Ifthisunitisconnectedtoauesystemotherthanthewayexplained
inthismanual,itwillnotfunctionproperly.

InstallationMUSTincludeatleast3-feetofverticalpipeoutsidethehome.Thiswillcreatesomenaturaldrafttoreducethe
possibilityofsmokeorodorduringapplianceshutdownandkeepexhaustfromcausinganuisanceorhazardbyexposing
peopleorshrubstohightemperatures.Themaximumrecommendverticalventingheightis12-feetfor3-inchtype“PL”
vent.TotallengthofhorizontalventMUSTNOTexceed4-feet.Thiscouldcausebackpressure.Usenomorethan180
degreesofelbows(two90-degreeelbows,ortwo45-degreeandone90-degreeelbow,etc.)tomaintainadequatedraft.

AULlisted3-inchor4-inchtype“PL”pelletventexhaustsystemmustbeusedforinstallationandattachedtothepipe
connectorprovidedonthebackofthestove(usea3-inchto4-inchadapterfor4-inchpipe).Connectionatbackof
stovemustbesealedusingHi-TempRTV.Use4-inchventiftheventheightisover12-feetoriftheinstallationisover
2,500feetabovesealevel.
WerecommendtheuseofSimpsonDura-Vent
®
orMetal-Fab
®
pipe(ifyouuseotherpipe,consultyourlocalbuilding
codesand/orbuildinginspectors).DonotuseType-BGasVentpipeorgalvanizedpipewiththisunit.Thepelletvent
pipeisdesignedtodisassembleforcleaningandshouldbecheckedseveraltimesduringtheburningseason.Pellet
ventpipeisnotfurnishedwiththeunitandmustbepurchasedseparately.

Theinstallationmustincludeaclean-outteetoenablecollectionofyashandtopermitperiodiccleaningoftheexhaust
system.90-degreeelbowsaccumulateyashandsoottherebyreducingexhaustowandperformanceofthestove.
Eachelboworteereducesdraftpotentialby30%to50%.
Alljointsintheventsystemmustbefastenedbyatleast3screws,andalljointsmustbesealedwithHi-TempRTV
siliconesealanttobeairtight.Theareawheretheventpipepenetratestotheexteriorofthehomemustbesealedwith
siliconeorothermeanstomaintainthevaporbarrierbetweentheexteriorandtheinteriorofthehome.
Ventsurfacescangethotenoughtocauseburnsiftouchedbychildren.Noncombustibleshieldingorguardsmaybe
required.

Donotterminatetheventinanenclosedorsemi-enclosedarea,suchas;carport,garage,attic,crawlspace,undera
sundeckorporch,narrowwalkway,oranyotherlocationthatcanbuildupaconcentrationoffumes.
Theterminationmustexhaustabovetheoutsideairinletelevation.
Theterminationmustnotbelocatedwhereitwillbecomepluggedbysnoworothermaterials.

Installation