Control Operation During A Power Failure
In the event of a power failure, the valve will keep track of the time and day for 48 hours.
The programmed settings are stored in a non-volatile memory and will not be lost during a
power failure. If power fails while the unit is in regeneration, the valve will finish regenera-
tion from the point it is at once power is restored. If the valve misses a scheduled regen-
eration due to a power failure, it will queue a regeneration at the next regeneration time
once power is restored.
Exiting Programming Mode
At any time, press the “ MENU” to accept all changes and return to main page display.
1. Press DOWN to advance to VACATION MODE.
2. Press the SET/REGEN to change the value. Press UP OR DOWN to change the values.
Vacation mode is only used when home is left un-occupied for lengthy
amounts of time and the owner wishes to have a periodic flush of the softener
system. The unit will not operate properly if vacation mode is left on.
Setting Vacation Mode
OPTIONS
DESCRIPTION
1 CURRENT TIME
This option is the current time of day.
2 CURRENT DATE
This option is the current date. The date is used to track the last time the system regenerated.
3 NUMBER PEOPLE
This value is the number of people living in the home. It is used to calculate the amount of water
needed for daily use and the reserve capacity of the system.
4 WATER HARDNESS
This value is the maximum water hardness in grains per gallon of the raw water supply. It is used to
calculate the system capacity.
Yes
No
Level I User Program Mode
PARAMETER
5
This function may be activated by the user during a prolonged absence such as vacation. The system
will perform a brief backwash and rinse based on the advanced setting. The purpose is to keep the
water fresh in the softener tank and plumbing system.
Main Display
About The Water Softener System
MAY 8, 2009
9:05 AM
VOLUME REMAINING
1,125 GAL
REGENERATION
TIME 2:00 AM
LAST REGEN
MAY 4, 2009
CAPACITY
1,350 GAL
CURRENT FLOW
1.5 GPM
PEAK FLOW
5.8 GPM
REGEN DAYS
7 DAYS
REMAINING DAYS
5 DAYS
This valve is controlled with simple, user-friendly electronics displayed on a large LCD
screen. The main page displays the current date and time. In addition, the main page also
shows key valve information and statistics including; current capacity setting, volume re-
maining, date of last regeneration, current flow rate, and peak flow rate.