Safety Data Sheets (SDS)
Skin protection
Hand protection
It is a good industrial hygiene practice to minimize skin contact. For prolonged or repeated skin
contact use suitable protective gloves.
Other
Normal work clothing (long sleeved shirts and long pants) is recommended.
Respiratory protection
If engineering controls do not maintain airborne concentrations below recommended exposure
limits (where applicable) or to an acceptable level (in countries where exposure limits have not
been established), an approved respirator must be worn. Use a NIOSH/MSHA approved air
purifying respirator as needed to control exposure. Consult with respirator manufacturer to
determine respirator selection, use, and limitations. Use positive pressure, air-supplied respirator
for uncontrolled releases or when air purifying respirator limitations may be exceeded. Follow
respirator protection program requirements (OSHA 1910.134 and ANSI Z88.2) for all respirator
use.
Thermal hazards
None.
General hygiene
considerations
Always observe good personal hygiene measures, such as washing after handling the material
and before eating, drinking, and/or smoking. Routinely wash work clothing and protective
equipment separately from regular wash. Observe any medical surveillance requirements.
9. Physical and chemical properties
Appearance
Physical state
Solid.
Form
Panel.
Color
White surface; beige/gray core.
Odor
Low to no odor.
Odor threshold
Not applicable.
pH
9
Melting point/freezing point
2200 °F (1204.44 °C) (Slag wool)
Initial boiling point and boiling
range
Not applicable.
Flash point
Not applicable.
Evaporation rate
Not applicable.
Flammability (solid, gas)
Not applicable.
Upper/lower flammability or explosive limits
Flammability limit - lower
(%)
Not applicable.
Flammability limit - upper
(%)
Not applicable.
Explosive limit - lower (%)
Not applicable.
Explosive limit - upper (%)
Not applicable.
Vapor pressure
Not applicable.
Vapor density
Not applicable.
Relative density
0.23 - 0.28 (H2O=1)
Solubility(ies)
Solubility (water)
Very low solubility in water.
Partition coefficient
(n-octanol/water)
Not applicable.
Auto-ignition temperature
Not applicable.
Decomposition temperature
Not applicable.
Viscosity
Not applicable.
Other information
Bulk density
15 - 18 lb/ft³
VOC (Weight %)
N/A (solid) (see section 16 for further detail)
10. Stability and reactivity
Reactivity
Not available.
Chemical stability
Material is stable under normal conditions.
A
stro® Acoustical Ceiling Panels SDS US
917993 Version #: 01 Revision date: - Issue date: 23-December-2014