Instructions / Assembly

SUBMITTAL SHEET
USG
Interior
Panel &
Finishing
Solutions
DESCRIPTION
INTENDED FOR
LIMITATIONS
USG SHEETROCK
®
BRAND
MOLD TOUGH
®
PANELS
FIRECODE
®
X
5/8 in. (15.9 mm) Type X moisture- and mold-resistant panels for use on walls and ceilings
5/8 in. (15.9 mm) Type X wallboard with moisture and mold resistance
Feature a noncombustible, moisture- and mold-resistant gypsum core encased in moisture- and
mold-resistant, 100% recycled green face and brown back papers
Comply with ASTM C1396, Standard Specification for Gypsum Board, for 5/8 in. (15.9 mm) Type X,
water-resistant gypsum wallboard and exterior gypsum sot board
Underwriters Laboratories Inc. (UL) Classification as to fire resistance, surface-burning
characteristics and noncombustibility
Achieved GREENGUARD Gold Certification and qualifies as a low VOC emitting material
(meets CA 01350)
USG Sheetrock® Brand Mold Tough® Panels Firecode® X are 5/8 in. (15.9 mm) Type X panels that
feature a noncombustible, moisture- and mold-resistant gypsum core that is encased in moisture-
and mold-resistant, 100% recycled green face and brown back papers. When tested in accordance
with ASTM D3273, Standard Test Method for Resistance to Growth of Mold on the Surface of Interior
Coatings in an Environmental Chamber, the panels meet or exceed ASTM C1396 specifications.
The long edges of the panels are tapered, allowing joints to be reinforced and concealed with USG
Sheetrock® Brand joint treatment systems. The panels are UL Classified for fire resistance and can
be used in any UL design in which Type SCX panels are listed. On the face along the long edge of
each panel, the UL Type Designation is printed for easy identification by building inspectors.
Commercial or residential applications where 5/8 in. (15.9 mm) moisture- and mold-resistant
Type X panels are required
New or repair and remodel construction
Load-bearing and non-load-bearing wood- or steel-framed fire-rated walls
Interior tile substrate in dry locations or areas with limited water exposure
Protected exterior sot and ceiling applications
1. Avoid exposure to sustained temperatures exceeding 125 °F (52 °C).
2. Avoid exposure to excessive, repetitive or continuous moisture before, during and after
installation. Eliminate sources of moisture immediately.
3. Must be stored o the ground and under cover in accordance with Gypsum Association's
GA-801, Handling and Storage of Gypsum Panel Products.
4. Not suitable for use as a substrate for tile in wet areas such as tubs and showers, gang showers
and other areas subject to direct water exposure.
5. Use as a tile substrate is limited to tile installed according to the most current TCNA and
ANSI specifications. Please consult with the adhesive and tile manufacturers for their
recommendations for maximum size and weight parameters for use with gypsum board.
6. Not recommended for exterior sots and ceilings which project upwards and away from
the building proper.

Summary of content (4 pages)