Installation Instructions

tongue and groove or back
blocked at the unsupported
edges.
Wall Applications:
Maximum stud spacing:
16" o.c. for tile installation.
24" o.c. for non-tile
installations. Framing shall
be designed (based on stud
properties alone) not to
exceed L/360 deflection for
tile, L/240 for surfaces that
will be painted. Maximum
fastener spacing: 8" o.c. for
wood and steel framing; 6"
o.c. for ceiling applications.
Patching Compound
Use a high-quality patching
compound such as USG
Durock
Fast Finish Floor
Patch or equivalent
approved by the resilient-
flooring manufacturer.
Adhesive/Mortar
Meeting ANSI A136.1: Type I
ceramic tile adhesive.
Meeting ANSI A118.1: dry-set
mortar.
Meeting ANSI A118.4: latex
portland cement mortar.
Grout meeting ANSI A118.7.
Ceramic tile meeting ANSI
A137.1.
Waterproof Membrane
If waterproofing is desired,
use USG Durock
tile
membrane installed with
USG Durock
tile membrane
adhesive. See USG literature
piece CB492 for USG
Durock
tile membrane
product information.
Protect panels from the
elements with adequate
covering during delivery
and storage.
Store panels flat on an even,
dry surface. Allow panels to
acclimate to temperature
and humidity at job site
prior to installation.
Handle panels in an
upright position to prevent
breakage.
Incorrect
Correct
Incorrect
Handling