User guide

Structo-crete
structural concrete panels
weigh between 140 to 150 pounds per panel
and are designed to be carried and installed
by two people.
Because of the weight of these panels, it is
important that they are always laid flat on the
floor or flat over the framing, in a horizontal
position. Prior to installation on the floor framing,
panels may be placed on pallets or timbers.
Panels may be placed on pallets or timbers
spaced a maximum of 4 ft. o.c. with the end
supports within 1 ft. of the ends of the panel.
Structo-crete panels must never be stored in an
upright position, on their edges, leaning against
a wall or other vertical support. This creates a
tipping hazard. If these panels tip over they could
cause serious injury or death.
When placing pallets of material on a floor or
floor frame it is imperative that the pallet be
located over load bearing walls and framing that
are capable of supporting the total load of a 20
piece pallet, which ranges between 3000 to 3100
pounds. Consult a qualified structural engineer
or design professional, as required, for safe and
proper distribution of pallets of
Structo-crete
panels over a floor frame and/or floor structure.
Structo-crete structural concrete panels are cement based and are reinforced with glass fiber.
Wear protective gloves to prevent any irritation to hands from the cement or glass fiber.
Cut panels to size with a circular saw equipped with carbide-tipped blade and a dry dust collection device
or a water-dispensing device that limits the amount of airborne dust. Dust can contain silica. Wear safety
glasses and a NIOSH-approved N95 dust mask when cutting this panel.
Structo-Crete
Structural Concrete Panel
Tip Sheet
Material Handling
Manufactured by
United States Gypsum Company
550 West Adams Street
Chicago, IL 60661
SCP11/11-11
© 2011, United States Gypsum Company
Printed in U.S.A.
goods not in accordance with
current printed instruction or
for other than the intended
use. Our liability is expressly
limited to replacement of
defective goods. Any claim
shall be deemed waived unless
made in writing to us within
company:
Structo-crete,
USG, USG in stylized letters.
Notice
We shall not be liable for
incidental or consequential
damages, directly or indirectly
sustained, nor for any loss
caused by application of these
Product Information
See usg.com for the most
up-to-date product information.
Trademarks
The following trademarks
used herein are owned
by United States Gypsum
Company or a related
thirty (30) days from date it
was or reasonably should have
been discovered.
Safety First!
Follow good safety/industrial
hygiene practices during
installation. Wear appropriate
personal protective equipment.
Read MSDS and literature
before specification and
installation.
888 STRUCTO (787.8286)
structo-crete.com
usgdesignstudio.com

Summary of content (1 pages)