Table of Contents 1. Safety Notice ......................................................................................................... 3 2. What’s Included .................................................................................................... 4 3. Connector Table .................................................................................................... 5 4. Introduction ......................................................................................................
1. Safety Notice Review the following safety precautions to avoid injury and prevent damage to this product. To avoid potential risk, use this product only as specified and only for the purpose described in the instruction manual. To Avoid Fire and Personal Injury: Use correct power supply. Use only the power supply provided. Ensure that the AC power outlet is located near the product and is easily accessible. Ground the unit.
Provide proper ventilation. The operating temperature range is between 0º C and 40º C. The humidity range is between 20% and 80%, non-condensing. The cooling method is convection. Keep product surfaces clean and dry. Disconnect the power cable from the power source before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. Do not push objects into openings of this product. Never insert objects into the product through openings.
3.
4. Left to Right Decca 3-pin Label PRESHOW Decca 12-pin Label 9 10 11 12 Main Show - Stop Main Show - Stop Main Show - Start Main Show - Start Connection 240V AC/DC, 10 Amp Connection – Inputs. Momentary switch to ground. Input - GND Input - 2 Input - GND Input - 1 Introduction The CMSA-100 provides essential automation functionality when used with the USL CMS2200 Cinema Media Server. The unit can function entirely standalone using the front panel switches to exercise each automation circuit.
5. Option – 1 Option – 2 Option – 3 ON Option – 3 OFF Preshow – ON Preshow - OFF System Description Output Relays (Solid State) The CMSA-100 has 10 isolated solid-state relays with momentary outputs. These outputs are rated for 24V AC/DC at 150 mA. Output Relays (Power) The CMSA-100 provides two independent contact relay outputs. They are rated for 240 VAC at 10 A. These relays are configurable to be momentary or latching.
Mounting The CMSA-100 comes with two rack-mounting brackets. When attached in forward facing position, they provide a 19-inch standard rack mount solution. They may also be attached in a top or bottom facing position to provide a convenient wall or shelf mounting solution. In all cases, USL recommends mounting the CMSA-100 to provide a stable configuration and clean installation.
through. For example, pressing the Preshow On button would close the normally open contacts as long as the button is held down. The Preshow Off button would have no function. If installing into an equipment rack, install the mounting ears onto the CMSA-100 chassis and mount the unit in the rack. The CMSA-100 must be mounted in an enclosed equipment rack if it is switching more than 24V. Connect a safety ground to the ground stud on the rear panel of the CMSA-100.
The SMS interface for the CMS-2200 can be used to fully exercise the automation system and ensure it is functioning properly. 7. Compliance Certifications Low Voltage Directive 73/23/EEC. EN 60950 Information Technology, Video, and similar Electronic Apparatus. IEC 60950 Safety Requirements. CE, UL, cUL Safety and Overall Compliance.
8. Product Support USL proudly stands behind its products. We are ready to answer questions about the installation or operation of the CM-8E. Application notes, manuals, and other documents are available on our website. You may contact us by: Phone: +1 805 549 0161 E-mail: support@uslinc.com You may file a support ticket at: www.uslinc.com/support USL Inc. is interested in your comments. Please feel free to contact us with any comments or suggestions. 9.