to the Gnd pin.
7. The HI signal can be sourced from either the cinem a processor or the cin-
ema server. With no connection to the HI CTL (Pin 9 Phoenix C onnector),
the HI source will be the cinema process or. If HI CTL is grounded, the
source will be the cinema server. The cinema automation system can also
be used to select HI sources.
Connect and Test
8. Plug in the Phoenix connector, BNC, DB25 input and output as needed.
9. Plug in the power supply into the DAX and i nto the lin e.
10. Check the LED for the correct HI source: Green = Analog, Red = AES
11. Run source material and verify proper levels and audio quality at the user
end.
Specifications
Input Voltage: 12VDC, 1A
HI/VI-N AES Source:
-20dBFS reference
Internally selectable choice between
Dolby 7/8
DCI 7/8, 9/10, 13/14, 15/16
BNC
HI Analog Input: 300mVrms = 0dBr via Phoenix type connector
HI Source selection: via Phoenix type connec tor
Analog Outputs: 300mVrms = 0dBr via Phoe nix type connector
Frequency Response (all inputs): 20-20kHz +/- 0.5dB
Noise (A wtd’d) (all inputs): <-80dBr