DAX-602/802 Digital to Analog Converter 181 Bonetti Drive San Luis Obispo, CA 93401 USA ph: +1 805-549-0161 fax: +1 805-549-0163 www.uslinc.
DAX-602/802 INSTRUCTION MANUAL -2- Ultra Stereo Labs, Inc.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. TABLE OF CONTENTS Warranty.......................................................................2 Safety Notices..............................................................4 Regulatory Compliance................................................5 DAX Background........................................................10 Front Panel Designations...........................................11 Rear Panel Designations.........................................
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Safety Notices Review the following safety precautions to avoid injury and prevent damage to this product. To avoid potential risk, use this product only as specified and only for the purpose described in the instruction manual. To Avoid Fire and Personal Injury: • Use correct power supply. Use only the power supply provided. Ensure that the AC power outlet is located near the product and is easily accessible. • Observe source ratings.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. REGULATORY COMPLIANCE EN 60950-1 The EN 60950-1 standard specifies the safety design requirements that reduce or eliminate the risk of personal injury to both the product user and service personnel. This product is designed and tested to meet the standards of the International Electrotechnical Commission (IEC) European Norm EN 60950-1, IEC 60950-1 (the standard for information technology equipment including electrical business equipment).
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. • Fournissez Ventilation Adéquate. La température dufonctionnement devrait être entre 0° C et 40° C. • L’humidité devrait être 20% et 80%. La méthoderefroidissante est par convection et un ventilateur interne. • Gardez les Surfaces du Produit Nettoient et Sec. • Déconnectez le câble du pouvoir de la source du pouvoir avant de nettoyer. N’utilisez pas de nettoyeurs. liquides ou de nettoyeurs de l’aérosol Utilisez un tissu humide pour nettoyer.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. tential elektrischen Schocks zu vermeiden muß der Boden-Schaffner korrekt sein. • Beobachten Sie Quelle-Klassen. Risiko von Feuer oder elektrischem Schock zu vermeiden muß de Macht-Quelle 100 sein-240 VAC 50-60 Hz. • Operieren Sie dieses Produkt mit Irgendwelchen Gehegen nicht, die geöffnet wurden, oder entfernen Sie. • Vermeiden Sie Ungeschützten Schaltkreise.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Sicherheit-Standard Der EN 60065 Standard schreibt Sicherheit-Entwurf-Anforderungenvor, der reduzieren oder das Risiko persönlicher Verletzung zu sowohl dem Produkt-Benutzer als auch Dienst-Personal ausschließen.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Equipment Class Type A: Equipment that is intended for connection to the building power supply wiring via nonindustrial plugs and sockets or via appliance couplers, or both. Disposal and Recycling Wheelie-Bin Symbol The Wheelie-Bin symbol is attached to this product in compliance with the EU Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE).
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. DAX Background The DAX unit was designed as a simple Digital to Analog Converter which would accept up to 10 AES/EBU conforming signals and convert them into multi-channel analog audio. There are two versions available. The DAX-802 converts 5 screen channels, 2 surrounds and the subwoofer/LFE. The DAX-602 is almost the same but does not convert LC and RC screen channels.
- 11 - Power Indicator - Indicates when unit is powered on. Signal Presence Indicators - indicates when signal exceeds -30dB Power Indicator - Indicates when unit is powered on. DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc.
1. Input Power - 12VDC @ 1A power supply 2. Digital Input - AES/EBU balanced line input. Both USL and DMA8 connector formats are supported. 3. Ethernet Port - For communication with the user interface. 4. Hearing Impaired / Visually Impaired - Narration (HI/VI-N) Output - Balanced or unbalanced line audio output. 5. Surround Delay Select Switch - Allows the surround audio to be delayed. 6. Delay Active LED - Indicates when the delay switch is actual delay setting. 7.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Setting the Surround Delay The LS/RS channels may be delayed between 0 and 150ms in 10ms steps. Calculate the surround delay by using the following formula: D = L - (W/2) +20 Where D = Delay in ms L = Auditorium length in feet W = Auditorium width in feet. Using a small, flat bladed screwdriver, set the LS/RS DELAY control to the value closest to the calculated value.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Setting up the DAX-602 Mono/Surround mode: 1) Remove the four side screws that hold on the cover. 2) Place the two jumpers in the position shown in the picture below. 3) Replace the cover. (See page 18) 4) Adjust output levels Center: -6dB, Left/Right: -3dB, LS/RS: -6dB to prevent output overload.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. AES/EBU Channel Assignments: The Digital Cinema Initiative (DCI) specification defines only channel pairs (1-16) and not audio locations (Left , Right, etc.). Until the relationship is specified, USL will use those established previously in the cinema industry. Two AES/EBU pinouts are commonly used in the industry. The DMA8 pinout is the Dolby® standard. The USL pinout was specified in a SMPTE recommended practice that was never published.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Analog Output Connector: (25 pin D sub Male) (Balanced or Unbalanced Line) Note: In Unbalanced mode the negative signal MUST be connected to ground. To minimize ground loop hum, the negative side of the output should be connected to ground at the signal desination instead of at the DAX. Twisted pair shielded cable should be used.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Web Interface The Ethernet interface on the DAX series allows remote monitoring and control of the device through a web interface. In addition, firmware upgrades are accomplished through the same web interface Initial Configuration The DAX units are shipped with a Dynamic Host Configuration Protocol client enabled. Further, the DAX supports the use of NETBIOS, so it is possible to connect to the device by name instead of by IP address.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Using IP Autoconfiguration and NETBIOS If no network with a DHCP server is available, connect a computer to the DAX using a network “crossover” cable. Some recent computers can use a standard “straight through” cable, but a crossover cable will always work. Many computers support “IP Autoconfiguration” where the computer chooses an IP address in the 169.254.x.y range.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. On the Configuration Page, you can change the Host Name (NETBIOS name) the device responds to. If you disable DHCP, you can set a static IP address, gateway, subnet mask, and DNS servers. DNS servers need not be specified. Once these are set, click on “Save IP Config and Reboot.” The DAX will restart with the new configuration. You will need to key the new IP address in to the address field of your web browser to re-establish contact.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Select the update file provided by USL, then click on “Update DAX.” The update process will take several minutes. When it is almost complete, you will see the LEDs on the front of the DAX flash. The web browser will then show an empty screen. You can then type the IP address or host name in the browser address field to re-establish communications with the unit.
DAX-602/802 INSTRUCTION MANUAL - 21 - Ultra Stereo Labs, Inc.
DAX-602/802 INSTRUCTION MANUAL - 22 - Ultra Stereo Labs, Inc.
DAX-602/802 INSTRUCTION MANUAL Ultra Stereo Labs, Inc. Revision History: 2/1/2009 - Original Version 9/1/2012 - Compliance Information Added; HI/VI-N Connector Changed. 5/7/2013 - Editorial updates, new rear panel for Rev. “D” depicted.
181 Bonetti Drive San Luis Obispo, CA 93401 ph: 1+ 805-549-0161 fax: 1+ 805-549-0163 www.uslinc.