Service manual

2DA/2DB
1-4-39
Maintenance
Description
item No.
U258 Switching copy operation at toner empty detection
Description
Selects if continuous copying is enabled after toner empty is detected, and sets the number of copies that can
be made after the detection.
Purpose
To be set according to user request.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select single or continuous copying using the up/down cursor keys. The selected item is displayed in
reverse.
Display Description
SINGLE Enables only single copying.
CONTINUE Enables single and continuous copying.
Initial setting: SINGLE
3. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.
U260 Changing the copy count timing
Description
Changes the copy count timing for the total counter and other counters.
Purpose
To be set according to user (copy service provider) request.
If a paper jam occurs frequently in the finisher when the number of copies is counted at the time of paper
ejection, copies are provided without copy counts. The copy service provider cannot charge for such copying.
To prevent this, the copy timing should be made earlier.
If a paper jam occurs frequently in the paper conveying or fixing sections when the number of copies is counted
before the paper reaches those sections, copying is charged without a copy being made. To prevent this, the
copy timing should be made later.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select the copy count timing using the up/down cursor keys. The selected item is displayed in reverse.
Display Description
FEED When secondary paper feed starts
EJECT When the paper is ejected
Initial setting: EJECT
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key. The screen for
selecting a maintenance item No. is displayed.