Service manual

Maintenance
Description
item No.
2DA/2DB
1-4-46
U901 Checking/clearing copy counts by paper feed locations
Description
Displays or clears copy counts by paper feed locations.
Purpose
To check the time to replace consumable parts. Also to clear the counts after replacing the consumable parts.
Method
1. Press the start key. The counts by paper feed locations are displayed.
2. Change the screen using the left/right cursor keys.
Display Paper feed locations
BYP Bypass tray
PF1 Drawer
PF2 First paper feeder*
2
PF3 Second paper feeder*
1
PF4 Third paper feeder*
1
DUP Duplex section*
1
*1: Optional. *2: Optional for 16 ppm model. Standard for 20 ppm model.
Clearing
1. Select the count to be cleared using the up/down cursor keys. The selected item is displayed in reverse.
However, PF2, 3, and 4 are displayed only and cannot be cleared.
2. Press the start key. The count is cleared.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The screen for selecting a
maintenance No. item is displayed.
U903 Checking/clearing the paper jam counts
Description
Displays or clears the jam counts by jam locations.
Purpose
To check the paper jam status. Also to clear the jam counts after replacing consumable parts.
Start
1. Press the start key. The screen for selecting an item is displayed.
2. Select the item using the up/down cursor keys.
3. Press the start key. The code by type is displayed.
Display Description
COUNT Displays/clears the jam counts
TOTAL COUNT Displays the total jam counts
Method: Displays/clears the jam counts
1. Change the screen using the left/right cursor keys.
2. Select the counts for all jam codes and select the ALL. Jam counts cannot be cleared individually.
3. Press the start key. The counts are cleared.
Method: Displays the total jam counts
1. Change the screen using the left/right cursor keys.
The total number of jam count cannot be cleared.
2. To return to the screen for selecting an item, press the stop/clear key.
Completion
To exit this maintenance item without changing the count, press the stop/clear key. The screen for selecting a
maintenance No. item is displayed.