Service manual

2DA/2DB
1-5-4
Section Jam code Description Conditions
Paper con-
veying
section
Transfer
section
Fixing sec-
tion
Exit sec-
tion
22
23
24
30
40
41
42
43
44
45
50
51
Multiple sheets in the
drawer 2*
2
(first paper
feeder)
Multiple sheets in the
drawer 3*
1
(second paper
feeder)
Multiple sheets in the
drawer 4*
1
(third paper
feeder)
Misfeed in registration/
transfer section
Misfeed in the fixing sec-
tion (paper feed from by-
pass tray)
Misfeed in the fixing sec-
tion (paper feed from
drawer)
Misfeed in the fixing sec-
tion (paper feed from first
paper feeder*
2
)
Misfeed in the fixing sec-
tion (paper feed from
second paper feeder*
1
)
Misfeed in the fixing sec-
tion (paper feed from
third paper feeder*
1
)
Misfeed in the fixing sec-
tion (paper feed from du-
plex section*
1
)
Misfeed in the exit sec-
tion
Misfeed in the job sepa-
rator*
1
The registration switch (RSW) does not turn off within 6320
ms of registration switch (RSW) turning on.
The registration switch (RSW) does not turn off within 2780
ms of drawer paper feed clutch 1 (DPFCL1)*
2
turning on.
The drawer feed switch 1 (DFSW1)*
2
does not turn off within
6320 ms of drawer feed switch 1 (DFSW1)*
2
turning on.
The rdrawer feed switch 1 (DFSW1)*
2
does not turn off within
2490 ms of drawer paper feed clutch 2 (DPFCL2)*
1
turning on.
The drawer feed switch 2 (DFSW2)*
1
does not turn off within
6320 ms of drawer feed switch 2 (DFSW2)*
1
turning on.
The rdrawer feed switch 2 (DFSW2)*
1
does not turn off within
2490 ms of drawer paper feed clutch 3 (DPFCL3)*
1
turning on.
The registration switch (RSW) does not turn off within 2340
ms of drawer feed switch 1 (DFSW1)*
2
turning on.
The registration switch (RSW) does not turn off within 2340
ms of drawer feed switch 1 (DFSW1)*
2
turning off.
The registration switch (RSW) does not turn off within 1760
ms of duplex paper conveying switch (DUPPCSW1)*
1
turning
on.
The exit switch (ESW) does not turn on within 3020 ms of the
registration motor (RM) turning on.
The exit switch (ESW) does not turn on within 3020 ms of the
registration motor (RM) turning on.
The exit switch (ESW) does not turn on within 3020 ms of the
registration motor (RM) turning on.
The exit switch (ESW) does not turn on within 3020 ms of the
registration motor (RM) turning on.
The exit switch (ESW) does not turn on within 3020 ms of the
registration motor (RM) turning on.
The exit switch (ESW) does not turn on within 3020 ms of the
registration motor (RM) turning on.
The exit switch (ESW) does not turn off within 3020 ms of the
registration switch (RSW) turning off.
The exit switch (ESW) does not turn on within 3020 ms of the
registration motor (RM) turning on.
The job separator eject switch (JBESW)*
1
does not turn on
within 2050 ms of feedshift switch (FSSW) turning on.
The job separator eject switch (JBESW)*
1
does not turn off
within 2050 ms of feedshift switch (FSSW) turning off.
The job separator eject switch (JBESW)*
1
does not turn off
within 2050 ms of feedshift switch (FSSW) turning off.