Service manual

2DA/2DB
1-5-5
Section Jam code Description Conditions
Misfeed in the feedshift
section (paper feed from
bypass tray)
Misfeed in the feedshift
section (paper feed from
drawer)
Misfeed in the feedshift
section (paper feed from
first paper feeder*
2
)
Misfeed in the feedshift
section (paper feed from
second paper feeder*
1
)
Misfeed in the feedshift
section (paper feed from
third paper feeder*
1
)
Misfeed in the feedshift
section (paper feed from
duplex section*
1
)
Misfeed in duplex paper
conveying section*
1
The feedshift switch (FSSW) does not turn on within 6320
ms of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320
ms of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320
ms of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320
ms of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320
ms of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 6320
ms of feedshift switch (FSSW) turning on.
The feedshift switch (FSSW) does not turn off within 1530
ms of paper switchback.
The feedshift switch (FSSW) does not turn on within 1530
ms of paper switchback.
The duplex paper conveying switch (DUPPCSW)*
1
does not
turn off within 3280 ms of the feedshift switch (FSSW) turn-
ing on.
The duplex paper conveying switch (DUPPCSW)*
1
does not
turn on within 3280 ms of the feedshift switch (FSSW) turn-
ing on.
The duplex paper conveying switch (DUPPCSW)*
1
does not
turn off within 3280 ms of the feedshift switch (FSSW) turn-
ing off.
*1: Optional. *2: Optional for 16 ppm model. Standard for 20 ppm model.
52
53
54
55
56
57
60
Feedshift
section
Duplex
section