Service manual

2DA/2DB
1-5-15
Problem Causes/check procedures Corrective measures
(24)
An original jams in
the original convey-
ing section is indi-
cated during copy-
ing (An original size
error jam).
Jam code 72
(25)
An original jams in
the original convey-
ing section is indi-
cated during copy-
ing (An original jam
in the original con-
veying section 2).
Jam code 73
(26)
An original jams in
the original convey-
ing section is indi-
cated during copy-
ing (An original jam
in the original con-
veying section 3).
Jam code 74
(27)
An original jams in
the original
switchback section
is indicated during
copying (An original
jam in the original
switchback section).
Jam code 75
(28)
Original jams fre-
quently.
Broken DP timing switch*
1
actuator.
Defective DP timing
switch*
1
.
Check if the original con-
veying motor*
1
malfunc-
tions.
Broken DP timing switch*
1
actuator.
Defective DP timing
switch*
1
.
Check if the original con-
veying motor*
1
malfunc-
tions.
Check if the switchback
feedshift solenoid*
1
mal-
functions.
Broken DP timing switch*
1
actuator.
Defective DP timing
switch*
1
.
Check if the original con-
veying motor*
1
malfunc-
tions.
Check if the switchback
feedshift solenoid malfunc-
tions*
1
.
Defective original
switchback switch*
1
.
Check if the original con-
veying motor*
1
malfunc-
tions.
Check if the switchback
feedshift solenoid*
1
mal-
functions.
An original outside the
specifications is used.
The DP forwarding pulley
or DP paper feed pulley is
dirty with paper powder.
The DP paper feed pulley
and DP separation pad do
not contact correctly.
Check visually and replace DP timing switch if its actuator is bro-
ken.
Run maintenance item U244 and turn DP timing switch on and
off manually. Replace DP timing switch if indication of the corre-
sponding switch is not light.
Run maintenance item U243 and select the original conveying
motor to be turned on and off. Check the status and remedy if
necessary.
Check visually and replace DP timing switch if its actuator is bro-
ken.
Run maintenance item U244 and turn DP timing switch on and
off manually. Replace DP timing switch if indication of the corre-
sponding switch is not light.
Run maintenance item U243 and select the original conveying
motor to be turned on and off. Check the status and remedy if
necessary.
Run maintenance item U243 and select the switchback feedshift
solenoid to be turned on and off. Check the status and remedy if
necessary.
Check visually and replace DP timing switch if its actuator is bro-
ken.
Run maintenance item U244 and turn DP timing switch on and
off manually. Replace DP timing switch if indication of the corre-
sponding switch is not light.
Run maintenance item U243 and select the original conveying
motor to be turned on and off. Check the status and remedy if
necessary.
Run maintenance item U243 and select the switchback feedshift
solenoid to be turned on and off. Check the status and remedy if
necessary.
Run maintenance item U244 and turn original switchback switch
on and off manually. Replace original switchback switch if indi-
cation of the corresponding switch is not light.
Run maintenance item U243 and select the original conveying
motor to be turned on and off. Check the status and remedy if
necessary.
Run maintenance item U243 and select the switchback feedshift
solenoid to be turned on and off. Check the status and remedy if
necessary.
Use only originals conforming to the specifications.
Clean with isopropyl alcohol.
Check and remedy.