Service manual

2DA/2DB
1-5-36
Problem Causes Check procedures/corrective measures
(12)
The drawer paper
feed clutch* does
not operate.
(13)
The cleaning lamp
does not turn on.
(14)
The exposure lamp
does not turn on.
(15)
The exposure lamp
does not turn off.
(16)
The fixing heater
does not turn on
(C6000).
(17)
The fixing heater
does not turn off.
(18)
Main charging is not
performed.
Broken drawer paper feed
clutch coil.
Poor contact in the drawer
paper feed clutch connec-
tor terminals.
Defective drawer main
PCB.
Poor contact in the clean-
ing lamp connector termi-
nals.
Defective cleaning lamp.
Defective engine PCB.
Poor contact in the expo-
sure lamp connector termi-
nals.
Defective inverter PCB.
Defective engine PCB.
Defective inverter PCB.
Defective engine PCB.
Broken wire in fixing
heater M or S.
Fixing thermostat trig-
gered.
Broken fixing thermistor
wire.
Dirty sensor part of the
fixing thermistor.
Broken main charger wire.
Leaking main charger
housing.
Poor contact in the high-
voltage PCB connector
terminals.
Defective engine PCB.
Defective high- voltage
PCB.
Check for continuity across the coil. If none, replace the drawer
paper feed clutch.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U032 and check if YC8-3 on the drawer
main PCB goes low. If not, replace the drawer main PCB.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Check for continuity. If none, replace the cleaning lamp.
If the cleaning lamp turns on when YC3-7,8 on the engine PCB
is held low, replace the engine PCB.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Run maintenance item U061 and check if the exposure lamp
turns on with YC1-1 and YC1-6 on the inverter PCB go low. If
not, replace the inverter PCB.
Run maintenance item U061 and check if YC17-1 and YC17-6
on the engine PCB goes low. If not, replace the engine PCB.
If the exposure lamp does not turn off with YC1-1 and YC1-6 on
the inverter PCB high, replace the inverter PCB.
If YC17-1 and YC17-6 on the engine PCB are always low, re-
place the engine PCB.
Check for continuity across each heater. If none, replace the
heater M or S.
Check for continuity across thermostat. If none, remove the
cause and replace the thermostat.
Measure the resistance. If it is , replace the fixing thermistor.
Check visually and clean the thermistor sensor parts.
See page 1-5-27.
*: 20 ppm model only.