Service manual

2DA/2DB
1-6-33
(6) Adjusting magnification of the scanner in the main scanning direction
Perform the following adjustment if the magnification in the main scanning direction is not correct.
U067
(P. 1-6-36)
U053
(P. 1-4-13)
U065
(main scanning
direction)
U065
(auxiliary scanning
direction) (P. 1-6-34)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Also, perform “(7) Adjusting magnification of the scanner in the auxiliary scanning direction” (page 1-6-34) and “(9)
Adjusting the scanner center line” (page 1-6-36) after this adjustment.
Procedure
Original Copy
example
Copy
example 2
Figure 1-6-64
Enter maintenance mode.
Enter “065” using the numeric keys.
Yes
No
Start
End
Press the interrupt key.
Place an original and press
the start key to make a test copy.
Is the image correct?
Setting range: –25 – +25
Initial setting: 0
Changing the value by 1 changes
the magnification by 0.1%.
Increasing the value makes
the image wider, and decreasing it
makes the image narrower.
For copy example 1, increase the
value using the right cursor key.
For copy example 2, decrease the
value using the left cursor key.
Press the start key.
The new setting
is stored.
Select the “MAIN SCAN ADJ”
using the up/down cursor keys.
Press the start key.
Press the stop/clear key to
exit maintenance mode.