DDI602U-F1 Outdoor Dual PIR Detector Installation Sheet EN 1 2 3 4 5 6 © 2012 UTC Fire & Security. All rights reserved. 1/8 P/N 1069154U-F1 • REV 4.
7 8 9 10 11 12 13 2/8 P/N 1069154U-F1 • REV 4.
14 15 16 All three sensors must trigger to cause the detector to signal an alarm. The DDI602U-F1 uses triple detection technology to deliver precise, reliable presence detection. It is designed for use in CCTV and intruder alarm systems. Programmable options include a variable pulse count and a choice of three detection ranges: 10 m / 33 ft., 18 m / 59 ft., and 25 m / 82 ft. The integral dual-axis tilt sensor allows 180° of pan and 90° of tilt.
Mounting the unit Connecting the unit During installation, protect the electronics against water, as trapped moisture can affect or damage the unit. The DDI602U-F1 includes jumpers that let you configure internal end-of-line (EOL) resistor values, when EOL resistors are required. Values are: 1, 2.2, 3.3, 4.7, 5.6, and 6.8 kΩ. Figure 5 shows: 1. EOL resistor jumpers 2. Wiring points To mount the detector: 1. Drill the wall to accept the two fixing screws, the cable entry, and the tamper cup (if used).
Table 2 below summarizes typical masking configurations for use when the range option is set to 25 meters. Table 2: Masking configurations for maximum range Configuration Height (m / ft.) Tilt (°) Max. range (m / ft.) Reference Multibeam, optimum 3 / 10 0 25 / 82 Figure 9 Pet immunity [1] 1.5 / 5 −2 25 / 82 Figure 10 [1] Black area should be masked for pet alley applications up to 30 meters / 98 feet. [2] Black area should be masked for curtain coverage applications.
Resetting options Outputs NO To reset the detector to the default settings: 1. Silent, solid state, magnetically immune. Volt free relay, signal contact 24 VAC/DC at 50 mA with an integral 25 Ω series resistor. Remove the power from the detector. 2. Press and hold the programming button (see Figure 14, item 2). 3. Apply the power to the detector. 4. After the programming LED flashes, release the programming button. Alarm time 5 seconds.
2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info. Usage restrictions Only use the listed models in the following countries: DDI602U-F1 (10.525 GHz): USA Contact information www.utcfireandsecurity.com or www.