User's Manual
GE AccessSmart 313 Last Update July 6, 2005
25
4. TA: TA is the Time Schedule code (‘00’ ~ ‘10’) for the Reader#1 (Built-in Reader). When you present the
card to the Reader#1, the cardholder is only allowed the access of the door during the Time intervals of the
Time Schedule code entered to TA. To setup the Time intervals for each Time Schedule code, refer to the
Time Schedule Setup on the [F5 SETUP MENU]. If you want to access the door anytime for the cardholder
then enter the default Time Schedule code '00' for the value.
5. TB: TB is the Time Schedule code (‘00’ ~ ‘10’) for the Reader#2 (Exit Reader). When you present the
card to the Reader#2, the cardholder is only allowed the access of the door during the Time intervals of the
Time Schedule code entered to TB. To setup the Time intervals for each Time Schedule code, refer to the
Time Schedule Setup on the [F5 SETUP MENU]. If you want to access the door anytime for the cardholder
then enter the default Time Schedule code '00' for the value.
6. RD: RD is the Reader Assignment code for the cardholder. Code ‘0’ assigns for both readers (Built-in
Reader and Exit Reader), code ‘1’ only assigns Reader#1 (Built-in Reader) and code ‘2’ only assigns
Reader#2 (Exit Reader). If you put ‘1’ for RD (Only Reader#1 assigned) and try to exit through Reader#2
(Exit Reader) then GE313 generates an error message (“Access Door Error”) on the LCD display.
7. MA: MA is the Reader#1 (Built-in Reader) Operating Mode for the cardholder. If you put ‘1’ for MA,
Reader#1 is always operating on RF Only Mode.
‘0’ – System Operating Mode [F2 SETUP MENU]Æ [READER#1 MODE]
‘1’ – ID Only Mode
‘2’ – ID + Password Mode
8. MB: MB is the Reader#2 (Exit Reader) Operating Mode for the cardholder. If you put ‘1’ for MB,
Reader#2 is always operating on RF Only Mode.
‘0’ – System Operating Mode [F2 SETUP MENU]Æ [READER#2 MODE]
‘1’ – ID Only Mode
‘2’ – ID + Password Mode
9. LV: LV is the Output Operating Level for the cardholder. Output operating time can be set for each user.
To setup Output operating time for each level, refer to the Output Setting on the [F7 SETUP MENU].
‘0’ or ‘1’ – Level #1
‘2’ – Level #2
‘3’ – Level #3
‘4’ – Level #4
GE AccessSmart 313 Last Update July 6, 2005
26
8. OPERATION
8.1 NORMAL OPERATION
Power on
When the power is applied to GE313, the Red LED is turned on.
Registered card reading
When a registered card (or PIN) is read, the Door (Relay#1) will open for 3 seconds (Default) with the Green
LED on.
Exit Button
When the Exit button is pressed, the Door (Relay#1) will open for 3 seconds with the Green LED on.
Alarms
When an unregistered card is read, the access is denied and the Alarm (Relay#2) will be activated for 3
seconds with the Yellow LED on.
8.2 DEFAULT SETTING
When you operate the system for the first time or the system initialized, the factory setting values (default
settings) will be stored in the memory. You may change the settings for the desired application.