User's Manual

GE AccessSmart 313 Last Update July 6, 2005
53
* Default Output Setting for Input Circumstance
9.7.1 OUTPUT SETTING FOR READER#1 ID OK LEVEL 1
Output Time setting from 9.7.2 to 9.7.14 is the same as 9.7.1 RD1 ID OK LV1 Output setting.
OUTPUT
Door
Relay
(DR)
Alarm
Relay
(AR)
TTL#1
(T1)
TTL#2
(T2)
Buzzer
(BZ)
[1] Reader#1 ID OK LV1 03 00 00 00 00
[2] Reader#1 ID OK LV2 05 00 00 00 00
[3] Reader#1 ID OK LV3 05 00 00 00 00
[4] Reader#1 ID OK LV4 05 00 00 00 00
[5] Reader#1 ID Error 00 03 00 00 00
[6] Reader#1 T/S Error 00 03 00 00 00
[7] Reader#1 APB Error 00 03 00 00 00
[8] Reader#2 ID OK LV1 03 00 00 00 00
[9] Reader#2 ID OK LV2 05 00 00 00 00
[10] Reader#2 ID OK LV3 05 00 00 00 00
[11] Reader#2 ID OK LV4 05 00 00 00 00
[12] Reader#2 ID Error 00 03 00 00 00
[13] Reader#2 T/S Error 00 03 00 00 00
[14] Reader#2 APB Error 00 03 00 00 00
. You can program OUTPUT activating time when the user ID is granted the access from the Reader#1. The
value put here is value x second when the Time Unit set to 1 second and value/10 second when the Time Unit
set to 0.1 sec. This Output Time is applied for the users registered with Level#1 output.
You can set the time from 00 to 98 seconds (0.0 to 9.8 seconds if Time Unit set to 0.1 sec.) and if you put the
value “99”, the Output will activate forever until you reset the Output.
Press <4> or <6> key to select Input Sources then press <ENT> key to program the Output time.
DR: Door Relay Output Time
AR: Alarm Relay Output Time
T1: TTL#1 Output Time
T2: TTL#2 Output Time
BZ
:
B
u
zz
e
r
Ou
t
pu
t Tim
e
GE AccessSmart 313 Last Update July 6, 2005
54
9.7.2 OUTPUT SETTING FOR READER#1 ID OK LEVEL 2
This Output Time is applied for the users registered with Level#2 output.
9.7.3 OUTPUT SETTING FOR READER#1 ID OK LEVEL 3
This Output Time is applied for the users registered with Level#3 output.
9.7.4 OUTPUT SETTING FOR READER#1 ID OK LEVEL 4
This Output Time is applied for the users registered with Level#4 output.
9.7.5 OUTPUT SETTING FOR READER#1 ID ERROR
This Output Time is applied if the user is not registered to Reader#1.
9.7.6 OUTPUT SETTING FOR READER#1 T/S ERROR
This Output Time is applied if the user is T/S error to Reader#1.
9.7.7 OUTPUT SETTING FOR READER#1 APB ERROR
This Output Time is applied if the user is APB error to Reader#1.
9.7.8 OUTPUT SETTING FOR READER#2 ID OK LEVEL 1
This Output Time is applied for the users registered with Level#1 output.
9.7.9 OUTPUT SETTING FOR READER#2 ID OK LEVEL 2
This Output Time is applied for the users registered with Level#2 output.
9.7.10 OUTPUT SETTING FOR READER#2 ID OK LEVEL 3
This Output Time is applied for the users registered with Level#3 output.
9.7.11 OUTPUT SETTING FOR READER#2 ID OK LEVEL 4
This Output Time is applied for the users registered with Level#4 output.
9.7.12 OUTPUT SETTING FOR READER#2 ID ERROR
This Output Time is applied if the user is not registered to Reader#2.
9.7.13 OUTPUT SETTING FOR READER#2 T/S ERROR
This Output Time is applied if the user is T/S error to Reader#2.
9.7.14 OUTPUT SETTING FOR READER#2 APB ERROR
This Output Time is applied if the user is APB error to Reader#2.