User's Manual
GE AccessSmart 314 Last Update July 6, 2005
21
Figure: RS-485 Communication between multiple GE314 and a host PC
6.7 TCP/IP CONNECTION (OPTIONAL)
Optional TCP/IP Module is required for TCP/IP communication to the host PC.
1. Connect RJ45 plug, LAN cable of the network system to RJ45 jack of the GE314.
2. If you install multiple GE314 and only one TCP/IP port is available, you may connect one GE314 to
TCP/IP then connect all GE314 units to RS485 multiple communication shown above.
3. Set a different COMM ID for each GE314.
4. Install and run the GE314 Application Software.
Figure: TCP/IP Communication between multiple GE314 and a host PC
GE AccessSmart 314 Last Update July 6, 2005
22
7. BASIC SETTINGS
7.1 INITIALIZATION OF GE314
After the all installation and connections are completed, press and hold the Initialize button and put the power
(+12V DC) to GE314. The LCD will first display “Initialize OK? 1:YES, 0:NO”. Press <1> key if you want
to initialize the system. After all Initialization process is completed, the system is operating on normal mode
and the LCD displays “GE Security, GE314 [F1], Date Time”.
7.2 HOW TO ENTER THE SETUP MENU
To setup or to change the GE314 settings, you have to enter the SETUP MENU first. To do so, press <0> key
eight times (Default Master ID ‘00000000’) and <ENT> key from the Keypad. You now entered to the
SETUP MENU. There are 9 SETUP MENU and you first get into [F1 SETUP MENU]. You can move to
another SETUP MENU by pressing <F1> key to <F9> key button. For example, if you want to go to [F2
SETUP MENU] then press <F2> key, for [F5 SETUP MENU] then press <F5> key and so on. There are
several SUBMENU on each SETUP MENU and you can scroll up and down the SUBMENU by pressing
<4> and <6> key on each SETUP MENU. If you don’t press any key for 60 seconds or if you press <ESC>
key, GE314 will exit the SETUP MENU and return to normal operation mode. You can also change the
Master ID in the [F4 SETUP MENU].