User's Manual
GE AccessSmart 314 Last Update July 6, 2005
25
1. Scanning… The reader is waiting for the ID number to be registered. The card number will appear with a
beep sound when you present the card. ID number is 8digit number.
2. ID: ID number consists of 4~8 digit. Enter 4~8digit ID number (PIN) and press <ENT> key on the field.
3. PW: PW is the password which can be used to access the doors with RF + Password operating mode. It is
necessary to enter a default password (‘0000’) when you register an ID.
4. TA: TA is the Time Schedule code (‘00’ ~ ‘10’) for the Reader#1 (Built-in Reader). When you present the
card to the Reader#1, the cardholder is only allowed the access of the door during the Time intervals of the
Time Schedule code entered to TA. To setup the Time intervals for each Time Schedule code, refer to the
Time Schedule Setup on the [F5 SETUP MENU]. If you want to access the door anytime for the cardholder
then enter the default Time Schedule code '00' for the value.
5. TB: TB is the Time Schedule code (‘00’ ~ ‘10’) for the Reader#2 (Exit Reader). When you present the
card to the Reader#2, the cardholder is only allowed the access of the door during the Time intervals of the
Time Schedule code entered to TB. To setup the Time intervals for each Time Schedule code, refer to the
Time Schedule Setup on the [F5 SETUP MENU]. If you want to access the door anytime for the cardholder
then enter the default Time Schedule code '00' for the value.
6. RD: RD is the Reader Assignment code for the cardholder. Code ‘0’ assigns for both readers (Built-in
Reader and Exit Reader), code ‘1’ only assigns Reader#1 (Built-in Reader) and code ‘2’ only assigns
Reader#2 (Exit Reader). If you put ‘1’ for RD (Only Reader#1 assigned) and try to exit through Reader#2
(Exit Reader) then GE314 generates an error message (“Access Door Error”) on the LCD display.
7. MA: MA is the Reader#1 (Built-in Reader) Operating Mode for the cardholder. If you put ‘1’ for MA,
Reader#1 is always operating on RF Only Mode.
‘0’ – System Operating Mode [F2 SETUP MENU]Æ [READER#1 MODE]
‘1’ – ID Only Mode
‘2’ – ID + Finger(Password) Mode
‘3’ – ID + Password + Finger Mode
8. MB: MB is the Reader#2 (Exit Reader) Operating Mode for the cardholder. If you put ‘1’ for MB,
Reader#2 is always operating on RF Only Mode.
‘0’ – System Operating Mode [F2 SETUP MENU]Æ [READER#2 MODE]
‘1’ – ID Only Mode
‘2’ – ID + Password Mode
GE AccessSmart 314 Last Update July 6, 2005
26
9. LV: LV is the Output Operating Level for the cardholder. Output operating time can be set for each user.
To setup Output operating time for each level, refer to the Output Setting on the [F7 SETUP MENU].
‘0’ or ‘1’ – Level #1
‘2’ – Level #2
‘3’ – Level #3
‘4’ – Level #4
10. FP: FP is the Fingerprint Usage Flag (1 digit). You can assign the user who uses fingerprint or not.
‘0’ – User without Fingerprint
‘1’ – User with Fingerprint
3. How to put your finger to the scanner
When you enroll or verify your fingerprint, please place your finger to the scanner correctly.
Figure: How to put your finger to the scanner