8. OPERATION
8.1 NORMAL OPERATION
Power on
When the power is applied to GE314, the Red LED is turned on.
Registered card reading
When a registered card (or PIN) is read and his/her fingerprint is verified, the Door (Relay#1) will open for 3
seconds (Default) with the Green LED on.
Exit Button
When the Exit button is pressed, the Door (Relay#1) will open for 3 seconds with the Green LED on.
Alarms
When an unregistered card is read or his/her fingerprint is not verified, the access is denied and the Alarm
(Relay#2) will be activated for 3 seconds with the Yellow LED on.
8.2 DEFAULT SETTING
When you operate the system for the first time or the system initialized, the factory setting values (default
settings) will be stored in the memory. You may change the settings for the desired application.
GE AccessSmart 314 Last Update July 6, 2005
28
9. SETTING CHANGES
☞. To setup or to change the GE314 settings, you have to enter the SETUP MENU first. To do so, press <0> key
eight times (Default Master ID ‘00000000’) and <ENT> key from the Keypad. You now entered to the
SETUP MENU. There are 9 SETUP MENU and you first get into [F1 SETUP MENU]. You can move to
another SETUP MENU by pressing <F1> key to <F9> key button. For example, if you want to go to [F2
SETUP MENU] then press <F2> key, for [F5 SETUP MENU] then press <F5> key and so on. There are
several SUBMENU on each SETUP MENU and you can scroll up and down to SUBMENU by pressing <4>
and <6> key on each SETUP MENU. If you don’t press any key for 60 seconds or if you press <ESC> key,
GE314 will exit the SETUP MENU and return to normal operation mode. You can also change the Master ID
in the [F4 SETUP MENU].