9.5.3 HOLIDAY CODE
9.5.4 READER#1 MODE TIME SCHEDULE
9.5.5 READER#2 MODE TIME SCHEDULE
READER#2 MODE TIME SCHEDULE setting is the same as 9.5.4 READER#1 MODE T/S setting.
. Holiday Code is to link the Holiday Schedule to the Time Schedule. T/S has 5 Time Intervals for holidays and
this Time Intervals are only applied to the dates of this Holiday Schedule. Default Holiday Schedule Code is
‘00’ which means no holidays are applied to T/S.
Use <4> or <6> key to scroll up and down the T/S Code (01~10) and press <ENT> key to enter 2digit Holiday
Schedule Code and press <ENT> key to store Holiday Index to the memory.
Press <ESC> ke
y
to return to the menu.
. There are 3 system operating mode, RF Only Mode, RF+F/P Mode and RF+PW+F/P Mode. You can setup one
of the system operating mode from [F2 SETUP MODE]->[R1 MODE SETTING] menu. However, you want
to apply different operating mode for a certain Time Interval for all users. For example, you want to access the
door by just presenting the card for the time from 09:00 to 17:00 and you want to use Fingerprint verification
for the rest of the time. In this case, setup [R1 MODE SETTING] to RF+F/P Mode which is for the system
operating mode and program “01” T/S Code which includes a Time Interval 09:00-17:00 then link “01” T/S
Code to this function, R1 MODE T/S setting here.
To link a T/S Code (01~10) to Reader#1 Mode, press <ENT> key. Enter 2digit T/S Code and press <ENT>
key to store T/S Code to R1 MODE to the memory.
Press <ESC> key to return to the menu.
. There are 3 system operating mode, ID Only Mode, ID + Finger(Password) Mode and ID + PW + Finger
Mode.
You can select one of the system operating mode from [F2 SETUP MENU]->[READER#1 MODE SETTING]
however, you want to apply different operating mode
‘2’ – RF + Finger Mode
‘3’ – RF + PW + Finger Mode
GE AccessSmart 314 Last Update July 6, 2005
50
9.6 F6 SETUP MENU