User Manual
3
PrecisionLine RCR-PET
Understanding the LED
The multi-color LED located on the bottom of the sensor
indicates the status of the unit as described in the following
table.
Maintaining the Sensor
When installed and used properly, the sensor provides
years of service with minimal maintenance. You should walk
test the sensor annually to ensure proper operation.
SB01 Swivel Mount Bracket
For ceiling-mount applications that require 90 degree
coverage, an optional ceiling-mount swivel bracket (SB01) is
available. See Figure 5.
Figure 5. SB01 Swivel-Mount Bracket
After 30 minutes the LED will only indicate an alarm condi-
tion. Drop power to reset the walktest timer.
(Pet immunity not verified by UL.)
riahgnoL
pu)gnol"2(
.sbl08ot
riahmuideM
)gnol"5.1(
.sbl05otpu
riahtrohS
otpu)gnol"1(
.sbl03
dednemmocertoN
yellatepesU
noitacilppa
koonihCeilloCijnesaBnamreboD
yksuHretteShsilgnEreirreTredroBenaDtaerG
eldooPretnioPleinapSrekcoCdnuohyerG
reveirteRguPgodlluBhcnerFffitsaM
godpeehSeldooPyoTreirreTlluBiniMlluBtiP
drehpehSrenaremieWigroChsleWdranreB.tS
staC
Pet Immunity
When mounted properly, the RCR-PET sensor provides false
alarm immunity to dogs and similar animals. The size and
temperature of the animal, which is affected by the length of
the animal’s coat, affects the immunity to false alarms. Dogs
vary in body temperature by breed, a very warm-blooded dog
with short hair will not be as immune to false alarms as a
similar sized dog with long hair. Therefore, the acceptable
short hair dog is limited to a smaller (lighter) weight dog. See
the examples listed in the following table:
Important: You need to set J2 as close to the intended
coverage range as possible. Overshooting the coverage
area may cause false alarms.
J3 LED -
ON = LED enabled (factory default)
OFF = LED disabled
Setting the Jumpers
The sensor provides jumpers to select the detection range
and LED operation. See Figure 4.
J2 Range - Use the jumper to cover the center pin and the pin
indicating the desired range. No jumper = 27 feet (8.2m) and
under.
35 feet (10.7m) and under 27 feet (8.2m) and under
(Factory default)
18 feet (5.5m)and under 9 feet (2.7m) and under
9’
(2.7m)
9’
(2.7m)
18’
(5.5m)
18’
(5.5m)
35’
(10.7m)
35’
(10.7m)
27’
(8.2m)
27’
(8.2m)
9’
(2.7m)
9’
(2.7m)
18’
(5.5m)
18’
(5.5m)
35’
(10.7m)
35’
(10.7m)
27’
(8.2m)
27’
(8.2m)
LED Status
Red PIR and RCR detection. The sensor is in
alarm and the relay has switched.
Green PIR detection only (no alarm).
Yellow RCR detection only (no alarm).