Installation Instructions
6
AL-111X Arming Station
Menu Option Description
1 - Access LED Controls the blue Access LED (enabled by default). The blue Access LED may be
disabled if not required.
2 - Night Light A dimly lit keypad backlight provides the night light to easily locate the keypad in
dark locations (enabled by default). The night light may be disabled if not required.
3 - Keypad Backlight The keypad backlight turns on bright for night-time illumination of the key labels
(enabled by default). The keypad backlight may be disabled if not required.
4 - Egress Control The RAS is fitted with an Egress (Exit) control port (IN) on the wiring connector. When
connected to a simple push button (see Egress Control and Open Collector), the OUT (open
collector terminal) may be used to control a door relay.
There are three options to choose from:
• Egress Only - This option requires a simple push button to be connected to the IN
terminal. A press of the button will release the door lock relay. Used for a quick exit
from an area (enabled by default).
• Egress + Arm/Disarm - This option is used to arm and disarm areas. See the control
panel programming manual for details.
• Egress Disabled - When the IN terminal is not used, it is recommended that it be
disabled.
5 - Reserved Menu 5 is reserved for future development.
6 - Factory Defaults This option returns all RAS settings to the following factory defaults (as applicable):
1. Access LED Enabled
2. Night Light Enabled
3. Keypad Backlight Enabled
4. Egress Control Egress Only
7. Security Mode Secured Mode
8. Valid Card Flash Enabled
9. Protocol Options Wiegard format
10. Card Beep Enabled
11. Option Card Enabled
Note Menu options 7 through 12 apply only to Smart Card reader (AL-1115 and AL-1116) RAS.
7 - Security Mode This option selects the type of user card the AL-1115 and AL-1116 reader will recognize. The
reader will recognize configuration and default cards in both modes. The modes are as
follows:
• Secured Mode - Only cards programmed on AL-1632 programmers will be recognized
in this mode (default setting). The 4-byte security password is used.
• Unsecured Mode - The reader will recognize blank or un-programmed cards only, by
using the card’s unique serial number. The 4-byte security password is not used.
Unsecured mode requires the use of an expanded memory system.
8 - Valid Card Flash This option enables (default setting) and disables the blue LED flash when a valid card is
badged at an AL-1115 or AL-1116 reader.
9 - Protocol Options This option selects the method by which an AL-1115 or AL-1116 reader sends data to the
panel. The options are as follows:
• Wiegand - Smart Card data is transmitted in the Wiegand protocol by default. The AL-
1632 programmer sets the number of bits (26- or 27-bit) when user cards are
programmed.
• Magnetic Stripe - The reader sends data to the panel in a 32-bit magnetic stripe card
format.
• Tecom Smart Card - This format is not implemented in the panel and should not be
selected.
10 - Card Beep This option enables the beep sounded when a card is badged at the reader (default setting) and
disables the beep.
11 - Option Card This option enables (default setting) and disables the use of reader configuration (option)
cards at the AL-1115 and AL-1116 reader. If an installer wishes to prevent the modification of
the reader setup by configuration card, this option should be disabled.
12 - Last Card This option displays the number of the last card badged at an AL-1115 or AL-1116 reader, in
the format: Facility Code, ID Number.