Operating Guide
LOCATION
1. Pump (A) should be located within 15 ft. of the water
source, and strainer (C) should be used at the end of
the inlet line.
NOTE: Make sure the inlet hose is NOT coiled or
kinked above or below water level.
The inlet line may be galvanized pipe, plastic pipe, or
reinforced hose. Be sure there are no leaks in the inlet
line, as this may reduce pump efciency or prevent
priming. Inlet line should be the same diameter as the
discharge line, or larger.
DO NOT use regular garden hose on the inlet line as
it will collapse during pumping.
Standard 3/4 in. garden hose may be used as a
discharge line. Keep the total length as short as
possible for best performance.
15 Ft.
Maximum Distance
to Water Source
1
INSTALLATION INSTRUCTIONS
In
Reinforced
hose
1. Attach hose adapters (B) and suction hose
(not provided) to pump. Make sure inlet connection
is air tight.
NOTE: Regular garden hose should not be used on
pump (A) inlet. It will collapse when the pump runs.
1
A
A
B
5
C