INSTALLATION INSTRUCTIONS
1. Make sure the sump basin is cleared of any
debris or sediment, then place pump (A) on a
hard surface inside the basin.
A
IL2042
1
2. Connect the discharge pipe, ttings and check
valve (not provided) to pump (A) discharge
according to local codes.The discharge pipe
should be the same size as the discharge of
pump (1-1/4 in.) or larger.
NOTE: Make sure there is enough room in the
basin for the oat to move freely. If the oat is
restricted, the pump will not operate.
3. Make sure your hands are dry and you are
not standing in water. Connect the pump to a
properly-grounded, GFCI electrical outlet.
WARNING: Do not use an extension cord.
NOTE: Tape or tie the electrical cord to the
discharge pipe to prevent it from interfering with
the motion of the float.
IL2044
115 V
GFCI Outlet
3
IL2043
Discharge pipe
and ttings
Check
valve