Instructions Manual

18
Copyright © 2011 Star Water Systems. All rights reserved.
19
Copyright © 2011 Star Water Systems. All rights reserved.
PRESSURE TANK INSTALLATION INSTRUCTIONS
WARNING: Not providing a relief valve
can cause extreme overpressure that could
result in personal injury and/or property
damage.
A properly sized pressure relief valve must
be installed on any installation where the
pump pressure can exceed the pressure tank’s
maximum working pressure or on systems
where the discharge line can be shut off or
obstructed. The relief valve drain port should
be piped to a drain.
7. Attach the pressure relief valve (sold
separately) to the remaining 1/2 in. opening
in the tank tee. (Fig 7)
8. To connect the pressure tank to the pump,
begin by threading a 1 in. coupling (sold
separately) onto the pipe tee. (Fig. 8)
9. Add additional couplings, unions and pipe
(all sold separately) as necessary to reach the
pump. (Fig. 9)
NOTE: Schedule 80 pipe recommended
10
20
30
40
50
60
70
80
Tape
10
20
30
40
50
60
70
80
Schedule 80 Pipe Shown
7
8
9