STAR 4 INCH SUBMERSIBLE WELL PUMP 2 & 3 Wire ® Español p.
TABLE OF CONTENTS Safety Information.........................................................................................................................2 Preparation....................................................................................................................................4 Assembly Instructions....................................................................................................................8 Electrical Hookup at the Pump........................................
SAFETY INFORMATION ELECTRICAL SHOCK HAZARD Can shock, burn or cause death. Ground pump before connecting to power supply. ELECTRICAL SHOCK HAZARD The pump is intended for use in a well. Motor frame must be connected to power supply ground or fatal electrical shock may result. ELECTRICAL SHOCK HAZARD NEVER leave fused disconnect switch or pressure control switch cover or covers open (either partially or completely) when not being worked on by a qualified electrician or repairman.
PREPARATION Before beginning installation of product, make sure all parts are present. Compare parts with package contents drawing. If any part is missing or damaged, do not attempt to assemble the product. Contact customer service for replacement parts. Estimated Installation Time: 2 hours.
PREPARATION Pump Performance Chart A Model Number HP GPM 1/2 5 3/4 5 1 5 Pumping Depth In Feet - Capaicities In Us Gallons At 40 Pounds Per Square Inch 20 40 60 80 100 120 140 160 180 200 225 250 275 300 325 350 400 450 500 550 600 650 5 GPM 8.3 7.9 7.5 7.1 6.7 6.3 5.9 5.4 4.9 4.2 3.5 2.4 8.7 8.5 8.2 8.0 7.7 7.5 7.2 6.9 6.5 6.2 5.7 5.3 4.9 4.4 3.1 8.7 8.5 8.3 8.1 7.9 7.7 7.5 7.2 6.9 6.7 6.3 6.0 5.4 4.6 3.7 2.5 2.4 9.0 8.8 8.7 8.5 8.4 7 GPM 8.2 8.
PREPARATION Control Box Chart B 3-WIRE SUBMERSIBLES ONLY Pump Model Control Box Pump Description Model Pump Model Control Box Pump Description Model 4H05A05001 127185 4H10A20301 137224 4H05A05005 not required SUB/4 5GPM CI 15STG 4H10G05001 127185 4H05A05301 127189 4H10G05005 not required SUB/4 10GPM CI 8STG 4H05A05305 not required SUB/4 5GPM CI 15STG 4H10G05301 127189 4H05A07301 127197 4H10G05305 not required SUB/4 10GPM CI 8STG 4H05A07305 not required SUB/4 5GPM CI 21STG 4H10G07301 12
PREPARATION Wire Size Chart C Model Number HP Volt Maximum Cable Length In Feet Using AWG Cable* #14 #12 #10 Model Number HP Volt Maximum Cable Length In Feet Using AWG Cable* #14 #12 #10 4H05A05001 1/2 110/115 100 160 250 4H10A20301 2 230 4H05A05005 1/2 230 400 650 1020 4H10G05001 1/2 110/115 100 160 250 4H05A05301 1/2 230 400 650 1020 4H10G05005 1/2 230 400 650 1025 4H05A05305 1/2 230 400 650 1020 4H10G05301 1/2 230 400 650 1020 4H05A07301 3/4 230
PREPARATION SUBMERSIBLE CABLE AND GROUND WIRE SELECTION 1 WARNING: Turn off power at the electrical service box before starting installation. Finding the Depth of Your Well: 1. Tie a small, heavy weight to the end of a cord (make sure the cord is at least 350 ft. long). Lower this weight into the well until it reaches the bottom. Take up any slack and mark the string at ground level. Pull the string from the well and measure from the weight to your mark. This is the depth of your well. Subtract 10 ft.
ASSEMBLY INSTRUCTIONS Follow step 1a and 1b below for Schedule 80 pipe or step 2a and 2b for black poly pipe. 1a Schedule 80 pipe (recommended) 1a. Apply thread tape and then thread the pipe directly into the pump discharge and tighten. For 1 in. pipe, you will also need a 1-1/4 in. x 1 in. reducer bushing, not shown. (Fig. 1a) Schedule 80 Pipe Submersible Pump 1b.
ASSEMBLY INSTRUCTRIONS 2b. Clamp pipe onto barbed end of male adaptor with two hose clamps (sold separately). (Fig. 2b) 2b 3. Firmly clamp the torque arrestor to the pipe approximately 2 to 4 ft. above the pump, using the two clamps provided with the torque arrestor. (Fig. 3) 3 Torque Arrestor IL1172 Approx. 4 ft. 4. Typical installations include the following components. Purchase these items separately depending on your need. (Fig.
ELECTRICAL HOOKUP AT THE PUMP Submersible Cable Splicing Pump is equipped with a lead wire assembly. The length of wire needed to attach to this lead wire assembly is equal to the distance from the pump in the well to the top of the well. Additional wire will be needed to run from the top of the well to the house. CAUTION: Follow instructions carefully to make a watertight splice. A leak in the splice can result in pump damage, blown fuses, overload protector tripping or electric shock hazard.
ELECTRICAL HOOKUP AT THE PUMP 3. Slide one shrink tube over each crimped joint. (Fig 3) 3 Metal Connector Shrink tube IL1145 4. Hold a torch (not included) approximately 6 in. from the center of the tubing and move it back and forth. Heat one set of wiring tubing at a time until seal is completed. During the heating process, keep all other wires/tubing away from heat to prevent melting together. Avoid overheating, as this may make the tubing brittle.
INSTALLATION INSTRUCTIONS LOWERING PUMP INTO WELL 1 CAUTION: If your pump depth will be 200 ft. or more, you may want to consider contacting a professional well pump installer. Piping filled with water, along with the weight of the pump, will be very heavy. Be sure to have assistance during pump installation. REMINDER: Pump and all piping must be assembled and securely connected before the assembly is lowered into the well. 1.
INSTALLATION 4. Add a well seal or pitless adaptor (sold separately) to allow for the pipe to be connected to house service. (Fig. 4) 4 Well Seal Installation At Top of Well Casing 4a. Pitless Adaptor Installation. Pitless adaptor should be installed below the frost line, and on the side of the well casing where the supply line will run from well, in accordance with the manufacturer’s instructions. (Fig.
PRELIMINARY TEST RUN WARNING: All electrical wiring or service should be done by qualified electrician. Be sure to test cable for continuity with an ohmmeter before starting the pump. 1. All wells should be flushed clear before allowing water into the house. (Fig. 1) 1 Outside Faucet Pump in Well Fuse Box 2. Open an outside faucet and allow water to run until water is clear of sand or any other impurities.
PRESSURE TANK INSTALLATION INSTRUCTIONS The purpose of the pressure tank (sold separately) is to allow a certain amount of water to be used before the pressure drops enough to cause the pump to start. Without a pressure tank, the pump would start and stop constantly, every time water is used. NOTE: Use thread tape and thread paste on all threaded connections. 1. NOTE: Check the air pressure of the tank with a tire gauge (sold separately) before the system is charged with water.
PRESSURE TANK INSTALLATION INSTRUCTIONS 4. Connect a 3/4 in. pipe (sold separately) and union (sold separately) to the 3/4 in. fitting. (Fig. 4) 4 Glue 5. Connect elbows, additional pipe and ball valve (all sold separately) as needed for your particular installation. (Fig. 5) 5 IL1154 Glue 6. Connect a drain valve (sold separately) to one of the 1/2 in. openings in the tank tee. (Fig. 6) 6 Tape 17 Copyright © 2011 Star Water Systems. All rights reserved.
PRESSURE TANK INSTALLATION INSTRUCTIONS WARNING: Not providing a relief valve can cause extreme overpressure that could result in personal injury and/or property damage. A properly sized pressure relief valve must be installed on any installation where the pump pressure can exceed the pressure tank’s maximum working pressure or on systems where the discharge line can be shut off or obstructed. The relief valve drain port should be piped to a drain. 7.
ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK For - 2-Wire Pumps - No Control Box Required. WARNING: This equipment is intended for installation by a technically qualified electrician. Failure to install it in compliance with national and local electrical codes may result in electrical shock or fire hazard, unsatisfactory performance, and equipment failure. WARNING: Always disconnect power source before working on or near the pump, its connected load and wiring.
ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK 3. Thread the cable from the house electrical service through one of the holes in the side of the pressure switch and tighten down the electric wire strain relief. 3 L1 CAUTION: Do not crush wire. (Fig. 3) L4 Strain Relief 4. Connect the two wires from the house electrical service to the outside pressure switch terminals (L1 and L4). (Fig. 4) 4 IL1162 L1 5.
ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK 6. Connect the two wires from the pump to the inside pressure switch terminals (L2 and L3). (Fig. 6) 6 L2 L3 L2 L3 IL1167 7. Connect green ground wires from the pump cable and the house electric cable to the two ground green screws on base of pressure switch. Replace switch cover. (Fig 7) 7 From Power Source From Pump Ground Screws 21 Copyright © 2011 Star Water Systems. All rights reserved.
ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK For - 3-Wire Pumps - Control Box Is Required. WARNING: This equipment is intended for installation by a technically qualified electrician. Failure to install it in compliance with national and local electrical codes may result in electrical shock or fire hazard, unsatisfactory performance, and equipment failure. WARNING: Always disconnect power source before working on or near the pump, its connected load and wiring.
ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK 3. Thread the electrical wire from pump into the right opening in the bottom of the control box and tighten the electric wire strain relief securely. (Fig. 3) 3 L1 L2 R Y B IL1174 4. Attach the black, yellow and red wires to the appropriate terminals marked “B”, “Y” and “R”. (Fig. 4) 4 L1 5. Connect the green ground wire from the pump to the green ground screw in the lower right corner of the control box. (Fig.
ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK 6. Thread the electrical wire from the pressure switch into the left opening at the bottom of the control box and tighten the electric wire strain relief securely. (Fig. 6) 6 L1 L2 R Y B IL1177 7. Connect the two wires from the pressure switch to the terminals in the control box marked L1 and L2. (Fig. 7) 7 L1 L2 R Y B L1 L2 R Y B IL1178 8.
ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK 9. Remove cover from pressure switch and screw the switch into the 1/4 in. opening on the top of the pipe tee. (Fig. 9) 9 10. Thread the cable from the house electrical service through one of the holes in the side of the pressure switch and tighten down the electric wire strain relief. 10 L1 L4 CAUTION: Do not crush wire. (Fig. 10) Strain Relief 1.
ELECTRICAL HOOKUP FROM THE HOUSE TO PUMP AND PRESSURE TANK 12. Thread the cable from the control box through the remaining hole in the side of the pressure switch and tighten down the electric wire strain relief. 12 CAUTION: Do not crush wire. (Fig. 12) 13. Connect the two wires from the control box to the inside pressure switch terminals (L2 and L3). (Fig. 13) 13 IL1165 L2 L2 L3 L3 IL1167 14.
TROUBLESHOOTING Problem Possible Cause Corrective Action Fuses blow 1. Incorrect voltage at motor 1. Check for correct wire size. Replace undersize wire. Check line voltage, contact power company if voltage is incorrect 2. Inspect fuse box wiring and correct. Install the proper fuses 3. Replace pressure switch or clean contacts 4. See control box checking and repairing procedures. Replace defective components 5. Check drop cable insulation resistance.
TROUBLESHOOTING Problem Possible Cause Corrective Action Motor runs, but delivers little or no water 1. Air locked pump 1. Normal delivery may resume if water pump is started and stopped at one minute intervals 2. Connect hose to service valve. Run water thru hose submerged in water in clear jar. Observe for air bubbles from hose outlet. If tank is standard type, the air volume control may be defective - replace; otherwise, have well checked for proper water level as pump may be drawing air.
TROUBLESHOOTING Problem Possible Cause Corrective Action Pump starts too often 1. Pressure switch 1. Readjust switch to wider operating pressure limits; replace defective switch 2. Check pressure in tank. Set at 2 lbs. below turn on pressure of the pressure switch. i.e. 30/50 pressure switch should have tank pressure of 28 lbs. 3. Throttle pump output at gate valve. If pump does not shut off, pump must be raised and defect repaired 2. Air volume in tank incorrect 3.
BOMBA PARA POZOS SUMERGIBLE DE 10,16 CM STAR ® 2 cables más puesta a tierra 3 cables más puesta a tierra IL0655 IL0656 MODELOS 4H05A05001 4H10A20301 4H05A05005 4H10G05001 4H05A05301 4H10G05005 4H05A05305 4H10G05301 4H05A07301 4H10G05305 4H05A07305 4H10G07301 4H05A10301 4H10G07305 4H05A10305 4H10G10301 4H05A15301 4H10G10305 4H07G05005 4H19A05001 4H07G05301 4H19A05305 4H07G05305 4H19A07301 4H10A05001 4H19A07305 4H10A05005 4H19A10301 4H10A05301 4H19A10305 4H10A05305 4H19A1
ÍNDICE Información de seguridad.........................................................................................................................31 Preparación ............................................................................................................................................. 33 Instrucciones de ensamblaje .....................................................................................................................37 Conexión eléctrica a la bomba ......................
INFORMACIÓN DE SEGURIDAD PELIGRO DE DESCARGA ELÉCTRICA La bomba está diseñada para uso en un pozo. La estructura del motor se debe conectar a un suministro de electricidad con descarga a tierra; de lo contrario, puede producirse una descarga eléctrica fatal.
PREPARACIÓN Antes de comenzar la instalación del producto, asegúrese de tener todas las piezas. Compare las piezas con el dibujo del contenido del paquete. No intente ensamblar el producto si falta alguna pieza o si éstas están dañadas. Póngase en contacto con el servicio al cliente para obtener piezas de repuesto. Tiempo de instalación estimado: 2 horas.
PREPARACIÓN Cuadro A de rendimiento de la bomba Artículo HP GPM 1/2 5 3/4 5 1 5 Profundidad de bombeo en pies - Capacidad en galones por minuto a 40 PSI (presión por pulgada cuadrada) 20 40 60 80 100 120 140 160 180 200 225 250 275 300 325 350 400 450 500 550 600 650 5 GPM 8.3 7.9 7.5 7.1 6.7 6.3 5.9 5.4 4.9 4.2 3.5 2.4 8.7 8.5 8.2 8.0 7.7 7.5 7.2 6.9 6.5 6.2 5.7 5.3 4.9 4.4 3.1 8.7 8.5 8.3 8.1 7.9 7.7 7.5 7.2 6.9 6.7 6.3 6.0 5.4 4.6 3.7 2.5 2.4 9.
PREPARACIÓN Cuadro B de la caja de control - Bombas de 3 cables más puesta a tierra Modelo de la bomba Modelo de la caja de control Descripción de la bomba Modelo de la bomba SUB/4 5GPM CI 15STG 4H10A20301 Modelo de la caja de control 4H05A05001 127185 4H05A05005 not required SUB/4 5GPM CI 15STG 4H10G05001 127185 4H05A05301 127189 4H10G05005 not required SUB/4 10GPM CI 8STG 4H05A05305 not required SUB/4 5GPM CI 15STG 4H10G05301 127189 4H05A07301 127197 4H10G05305 not required SUB/4 10GPM
PREPARACIÓN Cuadro C Calibres de cables Artículo # HP Voltios Longitud máx. de cable en pies según el AWG del cable* #14 #12 Artículo # HP Voltios #10 Longitud máx.
PREPARACIÓN 2. El descenso es el nivel más bajo de agua en el pozo una vez encendida la bomba. Si sabe cuál es el descenso, la bomba se puede configurar a 6,10 metros por debajo de este nivel. De todos modos, la parte inferior del motor siempre debe estar a por lo menos 3,05 m de la parte superior de la malla del pozo. (Fig.
INSTRUCCIONES DE ENSAMBLAJE 1b. Deslice las dos abrazaderas de manguera que vienen con el supresor de torsión (se vende por separado) sobre el extremo de una pequeña pieza de tubo Schedule 80 (aproximadamente de 4 pies de largo). Será más sencillo manipular la bomba si primero instala una pieza pequeña. Continúe con el Paso 3. (Fig. 1b) 1b Tubo de polietileno de color negro 2a.
INSTRUCCIONES DE ENSAMBLAJE 3. Sujete firmemente el supresor de torsión al tubo a una distancia aproximada de entre 0,61 m y 1,22 m sobre la bomba (A). Para ello, use las dos abrazaderas provistas con el supresor de torsión. (Fig. 3) 3 Supresor de torsión Aprox. 1,22 m 4. Las instalaciones habituales incluyen los siguientes componentes. Compre estos artículos por separado, según su necesidad. (Fig.
CONEXIÓN ELÉCTRICA A LA BOMBA Instrucciones para armar el empalme 1. Deslice un tubo contraíble negro del kit de empalme de tubo termocontraíble (se vende por separado) sobre cada cable (incluido el conductor de tierra verde) que sale de la bomba (A). (Fig. 1) 1 2. NOTA: Para cada cable que sale de la bomba (A), incluido el conductor de tierra verde, deslice el cable de la bomba en un extremo de un conector de metal del kit de empalme.
CONEXIÓN ELÉCTRICA A LA BOMBA 4. Mantenga una antorcha (no se incluye) aproximadamente a 15,24 cm del centro del tubo y muévala de adelante hacia atrás. Caliente un juego de tubería de cableado a la vez, hasta finalizar el sellado. Durante el proceso de calentamiento, mantenga todos los otros cables y las otras tuberías alejadas del calor para evitar que se derritan. Evite el sobrecalentamiento, ya que la tubería puede quebrarse. Si el líquido rezume desde el extremo del tubo, el sellado está completo.
INSTRUCCIONES DE INSTALACIÓN 1. Ate un extremo de la cuerda de seguridad (se vende por separado) de forma segura al ojal de seguridad de la bomba y el otro extremo a la tapa del pozo. Esta es la única medida de seguridad para evitar que la bomba caiga en el interior del pozo. (Fig. 1) 1 PRECAUCIÓN: Asegúrese de que el borde superior del entubado del pozo no tenga imperfecciones. Los bordes filosos o irregulares pueden cortar o raspar el cable y causar un cortocircuito.
INSTRUCCIONES DE INSTALACIÓN 4. Aplique sello para pozos o coloque un adaptador desmontable (se venden por separado) para que la tubería se conecte al servicio de la casa. (Fig. 4) 4 Instalación de un sello para pozos en la parte superior del entubado del pozo 4a. Instalación de adaptador desmontable. El adaptador desmontable se debe instalar por debajo de la línea de congelación y al lado del entubado del pozo, donde la tubería de suministro sale desde el pozo, según las instrucciones del fabricante.
EJECUCIÓN DE PRUEBAS PRELIMINARES ADVERTENCIA: La instalación de todo el cableado eléctrico y el servicio eléctrico deben estar a cargo de un electricista calificado. Asegúrese de probar la continuidad del cable con el ohmímetro antes de encender la bomba. 1. Antes de que el agua ingrese a la casa, es necesario descargar todos los pozos para que se limpien. (Fig. 1) 1 Grifo exterior Bomba para pozos Caja de fusibles 2.
INSTRUCCIONES DE INSTALACIÓN DEL TANQUE DE PRESIÓN El objetivo del tanque de presión (se vende por separado) es permitir que se use determinada cantidad de agua antes de que la presión disminuya lo suficiente como para que la bomba se encienda. Sin el tanque de presión, cada vez que se use el agua, la bomba se encendería y apagaría constantemente. NOTA: Use cinta para roscas y pasta para roscas en todas las conexiones roscadas. 1.
INSTRUCCIONES DE INSTALACIÓN DEL TANQUE DE PRESIÓN 3. Inserte un conector de 3/4” (se vende por separado) en la abertura de 3/4” de la tubería en T. (Fig. 3) 3 Cinta 4. Inserte un tubo de 3/4” (se vende por separado) y una unión (se vende por separado) en el conector de 3/4”. (Fig. 4) IL1153 4 Pegamento 5. Conecte los codos, la tubería adicional y la válvula de bola (todo se vende por separado), según sea necesario para su instalación en particular. (Fig.
INSTRUCCIONES DE INSTALACIÓN DEL TANQUE DE PRESIÓN 6. Conecte una válvula de desagüe (se vende por separado) en una de las aberturas de 1/2” en el conector en T del tanque. (Fig. 6) 6 Cinta ADVERTENCIA: Si no cuenta con una válvula de descarga, se puede generar una presión excesiva que podría ocasionar lesiones personales o daños a la propiedad.
INSTRUCCIONES DE INSTALACIÓN DEL TANQUE DE PRESIÓN 9. Agregue acopladores, uniones y tuberías adicionales (todo se vende por separado), según sea necesario para llegar a la bomba. (Fig.
CONEXIÓN ELÉCTRICA DESDE LA CASA A LA BOMBA Y EL TANQUE DE PRESIÓN 2. Retire la tapa del interruptor de presión y atornille el interruptor en la abertura de 1/4” de la parte superior de la tubería en T. (Fig. 2) 2 3.Enrosque el cable del servicio eléctrico de la casa a través de uno de los orificios al lado del interruptor de presión y apriete el aliviador de tensión del cable eléctrico. 3 L1 PRECAUCIÓN: No aplaste el cable. (Fig. 3) L4 Aliviador de tensión 4.
CONEXIÓN ELÉCTRICA DESDE LA CASA A LA BOMBA Y EL TANQUE DE PRESIÓN 5.Enrosque el cable de la bomba a través del orificio restante al lado del interruptor de presión y apriete el aliviador de tensión del cable eléctrico. (Fig. 5) 5 PRECAUCIÓN: No aplaste el cable. 6. Conecte los dos cables de la bomba a las terminales del interruptor de presión internas (L2 y L3). (Fig. 6) 6 IL1165 L2 L3 L2 L3 IL1167 7.
CONEXIÓN ELÉCTRICA DESDE LA CASA A LA BOMBA Y EL TANQUE DE PRESIÓN Para bombas de 3 cables + puesta a tierra- necesita una caja de control ADVERTENCIA: Este equipo se ha diseñado para ser instalado por un electricista con capacitación técnica. Si no se instala de acuerdo con los códigos eléctricos nacionales y locales, pueden producirse descargas eléctricas o incendios, el equipo puede funcionar mal e incluso fallar.
CONEXIÓN ELÉCTRICA DESDE LA CASA A LA BOMBA Y EL TANQUE DE PRESIÓN 3. Enrosque el cable eléctrico de la bomba en la abertura derecha en la parte inferior de la caja de control y apriete el aliviador de tensión del cable eléctrico de manera segura. (Fig. 3) 3 L1 L2 R Y B IL1174 4. Fije los cables negro, amarillo y rojo a las terminales correspondientes marcadas con “B”, “Y” y “R”. (Fig. 4) 4 L1 5.
CONEXIÓN ELÉCTRICA DESDE LA CASA A LA BOMBA Y EL TANQUE DE PRESIÓN 6. Enrosque el cable eléctrico del interruptor de presión en la abertura izquierda en la parte inferior de la caja de control y apriete el aliviador de tensión del cable eléctrico de manera segura. (Fig. 6) 6 L1 L2 R Y B IL1177 7. Conecte los dos cables del interruptor de presión a las terminales de la caja de control marcadas con L1 y L2. (Fig. 7) 7 L1 L2 R Y B L1 L2 R Y B IL1178 8.
CONEXIÓN ELÉCTRICA DESDE LA CASA A LA BOMBA Y EL TANQUE DE PRESIÓN 9. Retire la tapa del interruptor de presión y atornille el interruptor en la abertura de 1/4” de la parte superior de la tubería en T. (Fig. 9) 9 10. Enrosque el cable del servicio eléctrico de la casa a través de uno de los orificios al lado del interruptor de presión y apriete el aliviador de tensión del cable eléctrico. 10 L1 PRECAUCIÓN: No aplaste el cable. (Fig. 10) L4 Aliviador de tensión 11.
CONEXIÓN ELÉCTRICA DESDE LA CASA A LA BOMBA Y EL TANQUE DE PRESIÓN 12. Enrosque el cable de la caja de control a través del orificio restante al lado del interruptor de presión y apriete el aliviador de tensión del cable eléctrico. 12 PRECAUCIÓN: No aplaste el cable. (Fig. 12) 13. Conecte los dos cables de la caja de control a las terminales del interruptor de presión internas (L2 y L3). (Fig. 13) 13 IL1165 L2 L2 L3 L3 IL1167 14.
SOLUCIÓN DE PROBLEMAS Problema Los fusibles se queman. El motor no arranca. Los fusibles no se queman. Causa posible Acción correctiva 1. El voltaje que llega al motor es incorrecto. 1. Verifique que el calibre de cable sea el correcto. Reemplace los cables de menor calibre. Revise el voltaje de línea; póngase en contacto con la compañía eléctrica si el voltaje es incorrecto. 2. La caja de fusibles está defectuosa o los 2. Inspeccione el cableado de la caja fusibles son incorrectos.
SOLUCIÓN DE PROBLEMAS Problema El motor funciona, pero no extrae agua o extrae muy poca. Causa posible 1. La bomba está bloqueada con aire. Acción correctiva 1. Se puede reanudar la extracción normal de agua si se arranca y se detiene la bomba en intervalos de un minuto. 2. El agua del pozo tiene aire o gas. 2. Conecte una manguera a la válvula de servicio. Haga correr agua a través de la manguera sumergida en agua en un recipiente transparente.
SOLUCIÓN DE PROBLEMAS Problema La bomba funciona correctamente, pero no se apaga. Causa posible 1. Interruptor de presión. Acción correctiva 1. Reajuste el interruptor para disminuir la configuración de la presión de corte, limpie los contactos o reemplace el interruptor. 2. El nivel de agua es bajo. 2. Regule la salida de la bomba por medio de la válvula de compuerta o reajuste el interruptor de presión para disminuir la configuración de la presión de corte. 3. Hay una fuga en el tubo de salida o la 3.