TROUBLESHOOTING
Problem Possible Cause Corrective Action
Fuses blow 1. Incorrect voltage at motor 1. Check for correct wire size.
Replace undersize wire. Check
line voltage, contact power
company if voltage is incorrect
2. Defective fuse box or incorrect fuses 2. Inspect fuse box wiring and
correct. Install the proper fuses
3. Defective pressure switch 3. Replace pressure switch or clean
contacts
4. Control box malfunction 4. See control box checking and
repairing procedures. Replace
defective components
5. Defective drop cable insulation 5. Check drop cable insulation
resistance. Pump must be
pulled to replace defective cable
6. Motor malfunction 6. Check motor winding
resistance. Pump must be
pulled to replace defective
motor
7. Pump malfunction 7. If all above checks are good,
then pump is probably
bound. Pump must be pulled.
Check for sand or pump shaft
misalignment. Correct well
condition if sand is the problem
Motor won’t start.
Fuses don’t blow
1. No power to start motor 1. Check voltage at line side
of fuse box. Contact power
company if no power is reaching
box. Check voltage at load
side of fuse box and at other
control devices in circuit. Make
necessary corrections
2. Defective drop cable or motor 2. Check motor winding
resistance. Pump must be
pulled to replace defective cable
or motor