Material Safety Data Sheet
UTILITY MANUFACTURING CO., INC.
700 MAIN STREET, WESTBURY, NY 11590
(516) 997-6300 - FAX # (516) 997-6345
PASTE SOLDERING FLUX
Page2 14-205
MATERIAL SAFETY DATA SHEET
HANDLING AND STORAGE PRECAUTIONS: Avoid getting this product ON YOU or IN YOU. Wash hands after handling this
product. Do not eat or drink while handling this product. Store product in properly labeled, closed containers. Always use this
product in areas where adequate ventilation is provided.
SECTION VIII - FIRE AND EXPLOSION HAZARD DATA
EXTINGUISHING MEDIA: Extinguish with dry chemical, CO
2
, or a universal type foam.
FIRE AND EXPLOSION HAZARD: May decompose during contact with flames, heating elements, or in combustion engines releasing
irritating gases. Container may explode if heated due to resulting pressure rise.
FIRE FIGHTING PROCEDURES: Wear appropriate protective equipment including respiratory protection as conditions warrant (see
Section IV). Stop spill/release if it can be done without risk. Water spray may be useful in minimizing or dispersing vapors and
cooling equipment exposed to heat and flame. Avoid spreading burning liquid with water used for cooling purposes.
SECTION IX - PHYSICAL DATA
APPROXIMATE BOILING POINT (DEG F): >200 PER CENT VOLATILE: NONE
SPECIFIC GRAVITY (68 F): >1 FLASH POINT (TCC, DEG F): >300
RELATIVE EVAPORATION RATE (ESTIMATED): <1 PER CENT SOLUBILITY IN WATER: NEGLIGIBLE
VAPOR PRESSURE @20C mmHg (CALCULATED): <1
SECTION X - OTHER REGULATORY DATA
SARA HMIS
SECTION 302: NONE Health: 1
SECTION 311 & 312: ACUTE Flammability: 0
SECTION 313: See Section I.I Reactivity: 0
TSCA
All components are in full compliance CALIFORNIA PROPOSITION 65
with the TSCA inventory. NOT LISTED
RCRA CERCLA
Waste material would be a D002 ZINC CHLORIDE RQ: 1000 LBS.
CARCINOGENICITY:
NOT LISTED with NTP or IARC.
NOTICE
The supplier disclaims all expressed or implied warranties of merchantability or fitness for a specific use, with respect to the product or the information
provided herein, except for conformation to contracted specifications. All information appearing herein is based upon data obtained from manufactures
and/or recognized technical sources. While the information is believed to be accurate, we make no representations as to its accuracy or sufficiency.
Conditions of use are beyond our control, and therefore users are responsible for verifying the data under their own operating conditions to determine
whether the product is suitable for their particular purposes and they assume risks of their use, handling, and disposal of the product. Users also assume all
risks in regards to the publication or use of, or reliance upon, information contained herein. This information relates only to the product designated herein,
and does not relate to its use in combination with any other material or process.