Chemi 410 and BioChemi 500 Camera Installation and User Instructions UVP, LLC 2066 W. 11th Street Upland, CA 91786 Phone: (800) 452-6788 / (909) 946-3197 Fax: (909) 946-3597 Ultra-Violet Products Ltd. Unit 1, Trinity Hall Farm Estate, Nuffield Road, Cambridge CB4 1TG UK Phone: +44(0)1223-420022 Fax: +44(0)1223-420561 Web Site: www.uvp.com 81-0269-01 Rev.
Chemi 410 and BioChemi 500 Cameras 2 Introduction The high sensitivity, cooled CCD Chemi 410 and BioChemi 500 Cameras are designed for use with UVP’s BioSpectrum and EC3 Imaging Systems. The instruction manual covers assembly of the camera on the darkroom, installation of software and use of the camera. Refer to the system (manual for additional system information and the VisionWorksLS Software Manual or Help Files for software information.
Chemi 410 and BioChemi 500 Cameras 1. Camera USB cable 2. Camera and lens 3. Base mount 4. Bracket 5. Knob 6. Camera cover 7. Lens control box 8. 3 7 6 5 2 Thumb Nuts 5 8 3 4 1 Set up the darkroom and unplug all components from the power outlet. Refer to the BioSpectrum Imaging System Manual for more information. The base mount (3) is preassembled and attached to the BioSpectrum darkroom at the UVP factory. If not, secure the base mount to the darkroom with the long screws provided.
Chemi 410 and BioChemi 500 Cameras 4 Control Box UVP Lens Controller (pictured without camera and lens) Install the VisionWorksLS software to run the camera if not already installed. Refer to the PDF VisionWorksLS software manual on the Support CD or use the Help Files embedded in the software for more information.
Chemi 410 and BioChemi 500 Cameras 1. Camera USB cable 2. Chemi 410 Camera 3. Base mount 4. Bracket 5. Knob 6. Step-up ring 7. Auto zoom lens 8. Magnifier 9. Diopter 10. Screws and thumb nuts 5 3 2 1 6 5 4 7 8 9 10 11. Power cord 12. Camera power supply 11 12 Set up the darkroom and unplug all components from the power outlet. Refer to the BioSpectrum Imaging System Manual for more information. The base mount (3) is preassembled on top of the BioSpectrum at the UVP factory.
Chemi 410 and BioChemi 500 Cameras 6 Chemi 410 Camera Kit with Manual Lens Installing on the EC3 Imaging System The photograph shows parts required for assembly of the camera kit with the manual zoom lens onto the EC3 Imaging System. 1. USB cable 2. Chemi 410 Camera 3. Base mount and gasket 4. Bracket 5. Knobs 6. Step-up ring 7. Manual Lens 8. Magnifier 9. Diopter 10. Thumb nuts 2 3 1 6 10 5 7 8 9 4 11. Power cord 12.
Chemi 410 and BioChemi 500 Cameras 7 Connect the power supply and cable (11) to the camera and power source. Install the Camera drivers Open VisionWorks software. Connect the camera to a USB port on the computer with the USB cable provided and power connect the power supply to the camera and an appropriate power outlet. When the camera is first connected to the computer the “Found New Hardware” wizard will open. Select “Install from a list or specified location (Advanced)” and click the “Next” button.