Visi-Blue transilluminators are excellent for use with blue
460-470nm excitation samples and SYBR Green, SYPRO
Orange and GFP stains. A special amber camera filter
(50mm sq) is included when photographing gels.
Visi-Blue transilluminators and converter plates
minimize photonicking of DNA samples
The amber protective cover blocks blue light
transmission, allows visualization of most samples
above 500nm
VB-26V is a compact 8-watt model while the
VB-40V is a large format 25-watt model
VB-26V Visi-Blue Transilluminator patented design
converts UV light to 460-470nm.
Dimensions: Height includes amber cover
VB-26V 11D x 14W x 4.8H in. (279 x 356 x 122mm) Wt: 15 lb. (6.8 kg)
VB-40V 13.25"D x 19.13"W x 5.64"H (337 x 486 x 143mm)
Wt: 21 lb. (9.6 kg)
Ordering Information
VB-26 8-watt Variable Intensity
Filter Size 21 x 26cm
Replace. Tube, 365nm BLB
Replacement Filter
95-0461-01 (100-115V)
95-0461-02 (230V)
34-0056-01
38-0313-06
VB-40V 25-watt Variable Intensity
Filter Size 20 x 40cm
Replace. Tube, 365nm BLB
Replacement Filter
95-0433-01 (100-115V)
95-0433-02 (230V)
34-0060-01
38-0215-01
White/UV transilluminators have 20 x 20cm white light and
UV filter areas side by side. Design improves efficiency and
performance.
White light can be used for viewing Coomassie blue
and silver stained protein gels, autoradiographs and
microtiter plates
The UV side can be used for viewing Ethidium Bromide
and other stained gels
Dimensions: Height include UV blocking cover
13.25D x 19.13W x 5.64H in. (337 x 486 x 143mm)
Weight: 21 lb. (9.6 kg)
White/UV Transilluminator Easily switch between
the UV and white light sources.
Ordering Information
TLW-20 8-watt
365nm UV/White
Filter Size 20 x 20cm
Replacement Filter
95-0415-01 (100-115V)
95-0415-02 (230V)
38-0189-08
TMW-20 8-watt
302nm UV/White
Filter Size 20 x 20cm
Replacement Filter
95-0415-04 (100-115V)
95-0415-05 (230V)
38-0189-05
LMW-20 8-watt
365/302nm UV/White
Filter Size 20 x 20cm
Replacement Filter
95-0418-01 (100-115V)
95-0418-02 (230V)
38-0189-05
Replacement Tube, White
Replacement Tube, 365nm
Replacement Tube, 302nm
34-0056-01
34-0006-01
34-0042-01
Work areas of 21 x 26cm or
36 x 43cm.
White Light Transilluminators
offer uniform light diffusion
for autoradiographs, film pos-
itives, negatives, X-ray film,
microtiter plates and gels.
Plexiglass and glass filter
plates are sealed into the
unit for durability.
Ordering Information
TW-26 8-watt
Filter Size 21 x 26cm
Replacement Tube
Replacement Filter
95-0208-01 (115V)
95-0208-02 (230V)
34-0056-01
38-0161-04
TW-43 14-watt
Filter Size 36 x 43cm
Replacement Tube
Replacement Filter
95-0214-01 (115V)
95-0214-02 (230V)
34-0059-01
38-0165-01
Dimensions:
TW-26 9.5D x 13.25W x 4.25H in. (241 x 337 x 108mm)
Wt: 8 lb. (3.8 kg);
TW-43 19.1D x 16W x 4.25H in. (486x406x108mm)
Wt: 19 lb. (8.6 kg)
Visi-Blue
TM
Transilluminators
White/UV Transilluminators
White Light Transilluminators
P
P
PP
e
e
ee
n
n
nn
-
-
--
R
R
RR
a
a
aa
y
y
yy
L
L
LL
i
i
ii
g
g
gg
h
h
hh
t
t
tt
S
S
SS
o
o
oo
u
u
uu
r
r
rr
c
c
cc
e
e
ee
s
s
ss
A variety of lighted lengths and wavelengths are available
Lamp uses include:
Sterilization
Fluorescent inspections
Photochemical reactions
Interferometry
Chromatography
Photometric and fluorometric instruments
Spectroscopic wavelength calibration
Monochromatic sources for optical systems
and reference studies
Pen-Ray light sources are low-pressure, cold cathode
mercury UV lamps made of double bore quartz tubing.
The lamps are individually created by master craftsmen
to ensure quality and reliability. The lamps provide a high
degree of stable, isolated spectral line accuracy and long
life (3000+ hours).
Select Pen-Ray
Lamps are
available with a
choice of lighted
length and
diameter,
phosphor and
handle.
Rare Gas Lamp are available with Argon,
Krypton, Neon or Xenon fills.
Rare gas lamps incorporate the Pen-Ray
model 11SC-1 body but replace the Mercury
for other reactive ingredients. Ask about gas
combinations and custom designs.
Ordering Information - Standard Light Sources
11SC-1 254nm UV
Lighted Length/Dia:
Volts -Start/Operate:
90-0012-01
2.12/0.256 in. (53.8/6.5mm)
800V/270V
11SC-1L 365nm UV
Lighted Length/Dia:
Volts - Start/Operate:
90-0019-01
2.25/0.375 in. (57.2/9.5mm)
800V/270V
11SC-2 254nm UV
Lighted Length/Dia:
Volts: Start/Operate:
90-0020-01
0.75/0.256 in. (19.1/6.5mm)
800V/270V
3SC-9 254nm UV
Lighted Length/Dia:
Volts: Start/Operate:
90-0004-01
9.0/0.375 in. (228.6/9.0mm)
640V/56V
Call UVP for
additional models
and custom
designs
Lamp cord length: 16 in. (406mm) with standard connector;
different cable lengths and connectors are available.
Power supplies: provide optimum starting and operation of
the lamps. Use the recommended power supplies (ordered
separately) shown with each lamp.
Filter shields (optional): direct or modify the emission
output for model 11SC-1:
Shield A provides a 0.04 in. ID hole
Shield B has 0.31 x 0.63 in. window
Shield C has a 0.19 x 1.5 in. window
Ordering Information
Argon Fill
Krypton Fill
Neon Fill
Power Supply
90-0013-01
90-0014-01
90-0015-01
99-0057-01 (115V)
99-0057-02 (230V)
Neon-Mercury
Power Supply
90-0016-01
99-0055-01 (115V)
99-0055-02 (230V)
Xenon Fill
Power Supply
90-0017-01
99-0056-01 (115V)
99-0056-02 (230V)
Lamp Spectra
The graph below illustrates the relative emission intensities
of the mercury Pen-Ray lamps.
Spectral charts
and lamp
specifications
can be obtained
from UVP.
PEN-RAY
®
LIGHT SOURCES
Rare Gas Lamps
16
21
* Power supply is ordered separately.
Ordering Information - Power Supply
Power Supply
Open Circ. Voltage: 2300 VAC
Max. Pri./Lamp Current:
400 ma/18 ma (avg)
99-0055-01 (115V/60Hz)
99-0055-02 (220V/50Hz)
Rare Gas Lamps