Technical information

60
4 Functions during the Dive
III Uwatec
®
Aladin
®
Air Z O
2
Messages: An acoustic signal is sent if oxygen toxicity reaches 75%. The
symbol <CNS O
2
LIMIT> flashes continuously. The ascent arrow
and the O
2
-alarm-triangle is shown.
Response: Go to a smaller depth if necessary.
Messages: When oxygen toxicity reaches 100%, an acoustic alarm is sent
every 4 seconds. Also CNS O
2
% value, the ascent arrow and
the O
2
-alarm-triangle are flash continuously. See also page 79.
Response: Start ascent at once.
During an ascent and if the CNS O
2
% value does not increase
anymore (due to a lower partial pressure of oxygen), the acous-
tic warning and the ascent arrow are suppressed.
During the ascent, the display of the oxygen toxicity extinguishes
and the ascent rate is displayed. If the ascent is stopped, the dis-
play changes back to the indication of oxygen toxicity.
NO STOP
S
L
O
W
depth dive time
max. depth deco info
%
CNS O
2
LIMIT
tank data
bar
O
2
%
tank data
psi
O
2
tank data
bar
O
2
%
tank data
psi
O
2
4 sec
NO STOP
S
L
O
W
CNS O
2
LIMIT
depth dive time
max. depth deco info
%
CNS O
2
LIMIT
WARNING