User Manual
4
Table 1
Minimum gauge for extension cords
Volts Total length of cord in feet
120V 25 50 100 150
240V 50 100 200 300
Ampere rating more
than not more than
AWG
0-6 18 16 16 14
6-10 18 16 14 12
10-12 16 16 14 12
12-16 14 12
Not
recommended
NOTE: Only the applicable parts of the Table need to be included. For instance, a 120-volt product need not
include the 240-volt heading.
Figure 1
Method of securing extension cord
CORD
SET
APPLIANCE CORD
(A) TIE CORD AS SHOWN
(B) CONNECT PLUG AND RECEPTACLE
FOR ALL DOUBLE-INSULATED APPLIANCES
1) Replacement Parts
When servicing use only identical replacement parts.
2) Polarized Appliance Connections
To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other}