DT 2-wire Video Intercom System Technical Guide
CONTENT Section1 - Introduction 1 System Features- - - - - - - - - - - - - - - - - - - - - - - - - - System Capacity- - - - - - - - - - - - - - - - - - - - - - - - - System Extension- - - - - - - - - - - - - - - - - - - - - - - - - - - System Function- - - - - - - - - - - - - - - - - - - - - - - - - - --------------------------------------------------------------------------------------------------------------------- Section2 - Units and Installations Door Station-- - - - - - - - - - - - - 1 1 1 1 4
Section3 - Cables and Connections 28 General Rules for Installation-- - - - - - - - - - - - - - - - - - - - - 28 Connecting the Connectors - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -28 Installation Height - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -28 Door Station Install Condition- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -28 Table of Cabl
Section1 - Introduction System Features • • • • • • • With only 2 wires (no polarity) throughout the whole installation, the 2-wire DT system is a simplified installation system with minimum wiring and powerful features. The minimum wiring drastically reduces installation times and errors. By means of FM video modulation and ASK data transmission technology, system provides better protection against interference, which guarantees best color quality at all points of the installation.
Villa Application Although the DT system is mainly designed for the small apartment system usage, it can be used in villa or villa group applications. Multi Monitors can be installed in a family with the same User Code, or many houses can be connected as one system, and all of these Monitors can have calling conversation each other. 2 2 2 Apartment Applications This is the most common way that the system is used. One building or multi buildings can be connected as one system.
3
Section2 - Units and Installations Door Station Bit-4=off ON1 23456 DMR11/ID/D8 DMR11/D8 EP11/D24 Bit-4=on ON1 23456 DMR11/ID/S4 DMR11/S4 EP11/S12 Features • • • • • • • • • • • • Full anodize aluminum panel. SONY color CCD camera. camera angle adjustable. ID card access control Night-view LED with CDS light sensor. Backlit name plate for each button. Use DIP switches for multi Door Station configuration. Direct connect to electronic lock of 12Vdc. Exit button.
Parts and functions Camera Lens CDS Sensor Infrared LED 308 mm Speaker Microphone Name plate 298.5 mm Camera Angle adjustment Speaker Vol adjustment Connection Board Call button 18 mm 45 mm 114.5 mm 123 mm Place Name Plate Press down and shift right/left to open the transparent name plate cover, then insert the name paper, then put the plate cover back to the panel. Note that double button line panel can be opened both direction, single button line Can only be opened at right side.
Standard Installation 298.5 mm Camera Angle adjustment Open the mounting box of the panel, use a cross screw to adjust the view angle of the camera before installation. Installation with expanding panel Jointer*2 Note DT - System - Technical Guide +12V T/R - LK - (G ND)L K+( COM) T/R+ L1 L2 SET PA PB 12 3 123456 N.O .
T/R -T/R+ +12V LK - (GND) LK+(COM) RS-485 Terminal Descriptions N.O. EB+ SET EB - DMR11 Connection Board L1 L2 PA 1 2 3 PB BUS L1 L2 • • • • • • • • • • • • • +12V: 12VDC power output. LK-(GND): power ground. LK+(COM): electronically load activation relay contact common. NO.: electronic load activation relay normally open contact (the default setting for this terminal is NO, this terminal can be configured to NC, normally-closed contact by the DT CONFIG software).
DIP Switches settings Total 6 bits in the DIP switches can be configured. The switches can be modified either before or after installation. • Bit-1 and Bit 2 is for Door Station ID settings, when muti Door Stations are installed in the system, these two bit ON(1) OFF(0) ON 1 • • • • 2 3 4 5 6 = = must be set correctly, the first Door Station set to 00, the second one set to 01, the third one set to 10, the fourth one set to 11. If only one Door Station is installed, set to 00.
T/R - LK - (GND) LK+(COM) T/R+ N.O. EB+ EB - DMR11 Connection Board L1 T/ R - T/ R + L2 1 2 3 RS-485 +12VLK - (GND) PA PB SET LK +( CO M)N. O.EB +E B - SET +12V RS-485 Door Station Lock Connections BUS 1 L1 L2 PA PB 23 BUS 1. Direct lock connection Use the power of the system to supply for the electronic lock, so that the lock can connect to the Door Station directly, without an additional power supply for the electronic lock.
B. Connection for Power-- off-to-Unlock type: - DIPS +12V LK - (GND) LK+(COM) N.O. EB+ + 12V 300mA Jumper set to 2-3 position set to Normally Closed on the Unlock Relay mode on DT software. ON1 23456 DIPS-5: set to on, unlocking time is 5 seconds. EB - 12 3 2. Additional power supply When the electronic lock is over 12 Vdc, additional power supply for the lock is needed. • • • The power supply for the lock must be less than 48Vdc 1.5A.
Proximity ID Card Operation • • • • Up to 1000 user cards can be registered by the Door Station. Easy management with LED state and Sound hint. There are two master cards, one MASTER CARD ADD card and one MASTER CARD DELETE card, When adding a new master card, the old one will be replaced automatically. Card reading distance is from 3 to 5 cm. The Master cards are necessary when you add or delete user cards, Please keep the Master cards carefully.
Add user cards by Room: Press a certain button on the Door Station, then show the cards which to be assigned to this Room. Then press another button and show the cards ...... Show the MASTER CARD ADD card in standby Show the MASTER CARD ADD card again to confirm and exit. Delete user cards by Room: Show the MASTER CARD DELETE card in standby Press the button(s) that the Show the MASTER cards belong to on the Door Station.
Monitor Features POWER + IN-USE - LCD screen LED Indicator LCD CALL + Button UNLOCK - Button UNLOCK TA LK/ M O NI TOR Screen CALL button UNLOCK button TALK/MON IN-USE INTERCOM Touch Microphone Speaker MENU Button TALK/MON LED indicator button INTERCOM Button UNLOCK Button TALK/MON Button Microphone Speaker Mounting Hook Ventilation Vent Mounting Hook Connection Port Mounting Hook 123456 Connection Port Mounting Hook • • • • • • • • • Touch screen optional.
Terminal Descriptions Monitor Connection Board SW+ SWEXT-RING GND VIDEO S1 ON 123456 • SW+: Door bell call button. • SW-: Door bell call button. • • • EXT-RING: External ringer output(12Vdc 100mA) • S1: DIP switches for system configurations. • BUS: non-polarity bus line. GND: Ground. VIDEO: Video signal output. BUS Intercom function There are three kinds of intercom function available in the DT system. 1.
Step 1: Run the DT CONFIG software. Connect the USB-485 Convertor to the DMR11 Door Station and the PC, double click the software to make it running on the PC, then click the Namelist tap, the screen will be showed: Step 2: Edit the namelist. In the name input field, there is a Room No. column and a Name Label column, each User Code has a corresponding Room No. and a Name Label.
Camera Auto Switching When multi Door Stations or CCTV cameras are installed in the system, Monitor can display the video one after another. The Monitoring time for each Station or Camera must be set by the DT-CONFIG software manually to enable the Auto Switching function(DT-CONFIG-- >Parameter-- >Camera Switching Time). Also, you can touch the icon on the screen to monitor a specific camera only. Color Picture Memory Total 128 pcs picture can be stored in the Monitor.
User Code Setup In the DT system, every apartment must have a unique identification called User Code. The DIP switches are used to configure the User Code for each Monitor. • • • Bit-1 to Bit-5 are used to User Code setting. The value is from 1 to 32, which have 32 different codes for 32 apartments. When multi Monitors are installed in one apartment, these Monitors have to use the same User Code setting, and the Master/Slave mode should be set on the Monitor.
Monitor Extending Connection + CA LLU N LO C K - S1 TALK/M ON ON IN-USE 123456 S1 ON 123456 SW+ SW-EXT-RING GNDVIDEO L1 L2 L1 L2 1. Door Bell Call Button Additional door bell call button can be connected to the Monitor, so that the visitors can ring the door bell again in front of the user's apartment. When the call button is pressed, the Monitor will output ring tones but the screen will keep off, and the external ringer will ring at the same time(if a external ringer is installed). 2.
Accessories PS5 - Power Supply The PS5 power supply unit is designed for DT system to supply up to 32 Monitors and total 4 Door Stations at the same time. • • • • • • Universal AC input/full range. Multi protection: short circuit, overload, over voltage Cooling by free air convection DIN rail mounting. Support up to 32 Monitors Support up to 4 Door Stations. Dimension and Terminal 152.5 L • • (AC) 56 N (AC) 79 V- • L(AC): AC input. N(AC): AC input. : Earth Ground.
DIN Installation DPS PS5 DIN nail 85~260AC DT - System - Technical Guide 20
DPS DPS: This unit is a power supply adaptor for the PS5 or PS4 power supply, it transfers the power from the power supply to the suitable power for the non-polarity bus. Note that the DPS must work together with the PS5 or PS4 power supply. DPS Connect to Power Supply(PS5) Connect to Monitor Connect to Door Station Technical Specifications(DPS) Power 24Vdc (supplied by PS5) input: 18Vdc Power output: Power Consumption: 0.25W in standby, 0.
45 mm DPS/DBC Dimensions Direct Wall Mounting DIN Rail Mounting Use the screws to fasten the unit on the wall directly. Install on the DIN Rail.
DBC-4 Unit DBC-4 Distributor is a 4 output user distributor for DT system, to approach the star topology connection in the apartment system. See Section 3 Cables and Connection for detail connection information. set to 120 for the last DBC-4 on the building, the others must be set to HI.
DBC-4/DPS-4 Dimensions 140mm 13mm upward 62mm 88mm 70mm 84mm 32mm D C B A 36mm Trunk Bus HI 120 A/B/C/D port: Connect to Monitors/Door Station Trunk Bus: Bus input/output.
DCU Unit The DCU unit is a Multi function device which can connect 2 CCVT cameras and light/lock control.
60 mm Dimensions Direct Wall Mounting DIN Rail Mounting 80mm DT - System - Technical Guide 26
27
Section3 - Cables and Connections General Rules for Installation Connecting the Connectors Before screw the wire to the plug-in connector, it's important to process the wire in the correct way. See the following steps to connect the wire. 1. Strip the wire 2. Twist and bend it ~12mm 7~8mm 3. Put only the insulation-free part in the terminal Installation Height The recommended installation height of both Door Station and Monitor is from 160~165 cm.
Table of Cables and Distance The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance the system can reach. The farthest monitor DBC B C DPS When Monitor quantity < 20 Cable Usage A B C Twisted cable 2x0.75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 40 PS5 A When Monitor quantity > 20 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1.
System Wirings and Connections 1.
2.
3.
4.
5.
6.
7.
Busy State Management Calls and busy state are managed according to the programmed system times • • • • • Pick-up waiting time: this is the duration from when a call is made from a Door Station to when the called Monitor is picked up; the system will cut off the call after this period of time.(the default setting is 30 seconds) Maximum talking time: this is the duration time that the indoor user can talk to the out door visitor.
Door Station Function 1. Call Forwarding: Every call button on the Door Station has a button ID,which is associated with a Monitor ID(Monitor address or code). When a call button is pressed on a Door Station: • • Door Station free: the Door Station will output the call forwarding tone (a long beep(Di~) in every 3 seconds) and the nameplate light will blink. The Door Station will output an end of conversation tone at the end of the communication.
System Setup What’s User Code In 2-wire DT system, each Monitor installed in system must be programmed with a calling address or calling number, which is User Code. For Monitor, User Code is defined by 1~5 bits DIP switchers on the connection board, according the User Code rules. For example, if you want to program the Monitor’s User Code to be “03”, the Monitor’s 1~5 bit DIP switchers should be set as: ON, ON, OFF, OFF, OFF(please refer to User Code table at section2-Monitor).
What's Slave Address 2-wire DT system is capable of connecting up to 4 Monitors in one apartment, which means they will have the same User Code, and will be called simultaneously. In this condition, the Monitors should be programmed as below: • • • • 1. All the Monitors of same apartment must be programmed with the same User Code on the DIP switches. 2. There is only one master Monitor in the one apartment, and the Slave Address of the master Monitor is set to 0. Each Slave Monitor should be set from 1~3.
Online search Online search function is designed for the purpose of getting a quick view of the Monitors installing situations, or to check if each of them works or not. This is very useful for installation maintain. There are 3 different ways to use the Online Search function, manually search, use the ID tab and use the DT CONFIG software. When the Online search is acting, the Door Station will search every Monitor with the User Code from 1 to 32.
2. Use ID tag The Door Station will be equipped with an Online search Card with a card number of 16666666, which is designed for the online search only. Show the Online search card on the card window one time within 3 seconds, the Door Station will start to search the Right column Monitors; show the Online search card on the card window twice within 3 seconds, the Door Station will start to search the Left column Monitors 16666666 3.
Section5 - DT CONFIG Software Introduction DT-CONFIG software is a powerful configuration and debug tool to setup the 2-wire system. As simplified software tools, DT-CONFIG allows installers to check and program Door Stations rapidly, which is especially useful in complex installation. DT-CONFIG allows you to view device properties, modify parameters, re-locate Call Button and establish Name List in a PC and then download to the Door Station.
Interface Preview 1. Main Menu (Information Menu) The Information tab shows the product Model, Hardware Version, Software Version, Serial No. , Access Control, Access Card Number information. On the Installer's Information tab, user can input the Project Name and Block Name for this Door Station. Note: Series No. is a unique number programmed in factory and used for tracking. Refer to the software document in the disk for detail information. 2.
3. Name list Setup This menu is for the name list input and download operations. All user namelist can be input and download to the Door Station and the Door Station will send the namelist to every Monitor in the system. 4. Access Control The Access Control tab included two sub tabs, Device Operation and File Operation. The Device Operation is used to add/delete user cards or master cards.
5. Debug Tool The debug tool is very useful when trouble shoot or maintain the system: • • • • • • User Code Range: To change the User Code start and end address, only set valid range will save more time. Online Check Button: Use this button to start Online searching, and the result will be showed in list window.(Online search function is designed for the purpose of getting a quick view of the Monitors installing situations, or to check if each of them works or not.
DT User Code Programming Table page1/2 User code Bit state ON 01 12 3 4 5 6 ON 02 12 3 4 5 6 ON 03 12 3 4 5 6 ON 04 12 3 4 5 6 ON 05 12 3 4 5 6 ON 06 12 3 4 5 6 ON 07 12 3 4 5 6 ON 08 12 3 4 5 6 ON 09 12 3 4 5 6 ON 10 12 3 4 5 6 ON 11 12 3 4 5 6 ON 12 12 3 4 5 6 ON 13 12 3 4 5 6 ON 14 12 3 4 5 6 ON 15 12 3 4 5 6 ON 16 12 3 4 5 6 47 Room Name Label Remark
DT User Code Programming Table page1/2 User code Bit state Room Name Label Remark ON 17 12 3 4 5 6 ON 18 12 3 4 5 6 ON 19 12 3 4 5 6 ON 20 12 3 4 5 6 ON 21 12 3 4 5 6 ON 22 12 3 4 5 6 ON 23 12 3 4 5 6 ON 24 12 3 4 5 6 ON 25 12 3 4 5 6 ON 26 12 3 4 5 6 ON 27 12 3 4 5 6 ON 28 12 3 4 5 6 ON 29 12 3 4 5 6 ON 30 12 3 4 5 6 ON 31 12 3 4 5 6 ON 32(00) 12 3 4 5 6 DT - System - Technical Guide 48
GuangZhou Video-Tech Electronics Co.,Ltd www.v-tec.com.cn www.viewtech2wire.com DT System Technical Guide_V1.