VT596(F)/KP USER MANUAL(EN) 4 Wire Video Intercom System VT596/KP VT596F/KP Read this manual carefully before using the product, and keep it well for future use.
-1- 1.
-2•• •• •• •• •• •• •• •• •• •• •• •• •• •• JP/LK(Lock Control Jumper): To select the lock type: see section 4(lock connect) DIP Switches: Reserve. RS485:Used to update the program MIC: Adjust the volume of Microphone SPK: Adjust the volume of Speaker Main Connect Port: To connect the bus line and the electronic locks. DC+,DC-: Power supply connection port,16~24V, polarity. 1R: Power positive. +12V present when outdoor station calling or being monitored.
-3- VT596F/KP Mounting 1 2 adjust camera angle m 174mm 90m 52m m 4 core cable PS Drill a hole in the wall to match the size of the mounting box and attach to the wall.
-4- 4. System Wiring and Electric Lock Connection 0 # * TO Monitor JS/OS1 Red 1R 2W 3Y 4B 1R 2W 3Y 4B Yellow 9 Black 6 8 White 3 5 S- 2 4 S+ 1 7 1R 2W 3Y 4B DC- DC+ AC ~ PL Basic Connection Shielding Layer of the RVVP Cable Electric Lock Connection •• Mode1:Door Lock Controlled With Dry Contact Must install external power supply for lock,and nearly all kinds of electronic lock can be used.Incidentally,in this mode,you can continue talking and monitoring during unlock operation.
-5•• Mode2:Door Lock Controlled With Internal Power The lock can be directly connected with the door station and the power through monitor.During unlock operation,the monitor will close screen automatically. Note: 1 2 3 S- S+ PL 1.Electronic lock of power-on-to-unlock shoule be used. 2.The door lock is limited to 12V,and holding current must be less than 250mA 3.The door lock control is not timed from Exit Button(EB).
-6- Order Setting items Setting range Default value Setting code 1 Reset all settings 1234 - 00 2 Setting the master code 1234 01 3 Setting the key illumination time 1 ~ 12 digits Valid keys:0 ~ 9 10 to 99 seconds/ continually lit(00s) 10 seconds 02 4 Setting the unlock time 01 to 99 seconds 1 seconds 03 5 Setting the unlock mode 0:opened/1:closed opened 04 6 Operation tone settings 0:on/1:off on 05 7 Reset code settings 1234 - 06 8 function settings 0:Normal/1:R
-7- Setting items 1.Reset all settings 2.Setting the master code (Default Step 1 1234) Step 1 3.Setting the key illumination time (Default 10s) Step 1 Step 1 (red) ON Input the master code. (Default: [ 4.Setting the unlock time (Default 1s) (blue) OFF ] +[#] ) Step 2 Beep+, Beep Step 2 Step 2 Step 2 Input the setting code. Input the setting code. Input the setting code. Input the setting code.
-8- Setting items 5.Setting the unlock mode (Default 0(opened)) Step 1 6.Setting operation tone (Default ON) Step 1 Step 1 Step 1 (red) ON Input the master code. (Default: [ * 8. function setting (Default Normal) 7.Reset code setting (blue) OFF ] +[#]) Step 2 Beep+, Beep Step 2 Step 2 Step 2 Input the setting code. Input the setting code. Input the setting code. Input the setting code.
-9- Setting items 10.Interference resistant grade setting (Default 2) 12.Setting the code forTemporary1 Step 1 Step 1 13.Setting the code forTemporary2 Step 1 Step 1 (red) ON Input the master code. (Default: [ 14.Setting the code for user (blue) OFF ]+[#] ) Beep+, Beep Step 2 Step 2 Step 2 Step 2 Input the setting code. Input the setting code. Input the setting code. 09+# 18+# 19+# (red) ON (blue) ON (blue) ON Inputting of code (ex.
-10- 6. Unlock Operations Unlocking of user code When the registered user code has been input using the keypad (1~12 digits), the LED indicator (red) lights up, the buzzer sounds,and the electric door strike is unlocked.
-11- 7. Precaustions •• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust. •• The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit. •• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture..