IP 2-wire System Technical Guide IP network for DT System
Chapter 1 1.1. IP System Description 1.2. IP System Part List 1.3. IP System Features 1.4. IP System Typical Applications 1.5. Wiring Diagrams 1.5. 1 Connect with PC in single family system 1.5. 2 Connect Common Door Station in Apartment compound 1.5. 3 Connect Intercom point in network 1.5. 4 Connect Quad switched 4 Cameras in one CM-IPC node 1.5. 5 Connect Multi Door Stations in block system 1.5. 6 Optical Fiber connection for very long distance 1.5.
§§ 1.1 IP System Description 2-Wire systems do NOT need more cable wires to connect the components together. All the signal transfer for the system is sent via the two power wires in the power cable. IP technology is the most common and advanced network, and the direction of system integration. Now, 2-wire system and IP network are integrated. The IP network makes standalone 2-wire systems working together, so it can be used for complex residential blocks, even for large system.
§§ 1.2 IP System Part List Switchboard: IP-Agent software PC software The switchboard software may be installed on desktop or laptop pc. * Windows 7 OS is recommended * SQL server database is required exceptionally, if multi PC stations are installed HS-PC Handset kit for IP-Agent Handset with desk mount to connect with PC. Works with IP-Agent, to answer calls just by pick up the handset, and with 2 Unlock Buttons in panel. * One USB2.
IP Gateway Converter: DT-IPC IP Gateway Converter for 2-wire system * Set DIP switches correctly according to DS/ CDS usage IP Gateway Converter: CM-IPC IP Gateway Converter for CCTV camera DMR18 Digital keypad Door Panel * Note: Set ID Code to 0~3 for DS mode * Note: Set ID Code to 4 to CDS mode DMR11 and EP11 Series Direct-select Door Panel * Note: Can be used as Common Door Station directly DT-59X 1/2 Call Button Small Door Station * Work in Villa block, or Intercom Point in system * Note: For other
§§ 1.
§§ 1.4 IP System Typical Applications 1.4.1 Connect with PC in single family system TALK MENU MONITOR TALK MENU MONITOR DPS PS5-24V Video Surveilance PS4 PS5 DPS DT-IPC PC CM-IPC VT-QSW IP Home Network 1. Answer calls and release the door from PC 2. Monitoring Door Station camera or Video Surveillance cameras from PC 1.4.
-7- MENU MONITOR Ethernet(LAN) TALK MENU MONITOR DPS PS5 PC Station Switchboard DPS PS5-24V IP backbone network DT-IPC TALK Apartment DT-IPC TALK MENU MONITOR MENU MONITOR DPS PS5 DPS PS5-24V TALK Apartment Guard Station Switchboard SOS PS5 DPS Intercom Point DT-IPC IP-2 wire system technical guide CM-IPC one camera or 4 quad cameras PS4 PS5 7 4 1 * 3 6 9 # 2 5 8 0 RF CARD DT-IPC VT-QSW Video Surveilance DPS Common Door Station 1.4.
IP-2 wire system technical guide 1 2 ON ID=00 ON DT-IPC DPS Code=0, DIP-6=off 1 2 3 4 5 6 ON Code=13, DIP-6=off 1 2 3 4 5 6 ON Code=14, DIP-6=on 1 2 3 4 5 6 PS5 MENU MENU MENU MONITOR MONITOR MONITOR 85~260AC TALK TALK TALK AC~ MONITOR MENU MONITOR DPS PS5 DPS PS5-24V TALK Ethernet Switcher IP Home Network MENU DT-IPC TALK PC CM-IPC PS4 CM-IPC PS4 Video Surveilance §§ 1.5 Wiring Diagram 1.5.
-9- MONITOR 1 2 3 4 5 6 Code=2, DIP-6=on MENU MONITOR IP-2 wire system technical guide ON 123456 ID=00 TALK MONITOR MONITOR DT-IPC ON 1 2 3 4 5 6 DPS Code=1, DIP-6=on 1 2 3 4 5 6 ON Code=3, DIP-6=on 1 2 3 4 5 6 ON Code=29, DIP-6=on PS5 TALK TALK TALK MONITOR MONITOR MONITOR 85~260AC MENU MENU MENU MONITOR AC~ OUT IN ON MENU MENU MENU HI HI DBC-4 1 2 3 4 5 6 TALK TALK TALK A B C D Code=4, DIP-6=on 1 2 3 4 5 6 ON Code=30, DIP-6=on Code=31, DIP-6=on OUT IN
1.5.
1.5.
1.5.
-13- IP-2 wire system technical guide 9 # 0 * 6 8 3 2 5 7 RF CARD 4 DPS PS5 85~260AC ON MENU PC Station Switchboard 123456 ID=00 TALK MENU MONITOR MONITOR DPS Code=1, DIP-6=on 1 2 3 4 5 6 ON Code=3, DIP-6=on PC Station Switchboard DT-IPC ON 1 2 3 4 5 6 PS5 TALK TALK MONITOR MONITOR AC~ HI SOS Guard Station Switchboard 85~260AC MENU MENU SOS To block B,C,D Guard Station Switchboard DBC-4 1 DT-IPC Ethernet(LAN) PS4 Code=2, DIP-6=on 1 2 3 4 5 6 ON Code=
IP-2 wire system technical guide -14- 9 # * CDS 6 8 7 3 2 5 0 4 RF CARD 1 DS 7 * 4 1 DS 2 9 # 7 * 0 8 5 RF CARD 6 4 3 1 # 9 6 3 Common Entrance 2 2 PC Station Intercom Point 8 Guard Center PC Station DS Block D 5 Guard Station Guard Station Switchboard Block C 0 SOS SOS Switchboard Block B RF CARD Common Entrance 1 Network Cameras Block A * 7 4 1 0 8 5 2 RF CARD # 9 6 3 CDS DS
1.5.7 Optical Fiber connection for very long distance •• LAN network using fiber optic, brings insulation among the systems; this ensures a higher degree of immunity from lightning damages. •• Using IP as repeater can meet a large distance between the Door Station and Monitor.
Chapter 2 Product Introduction 2.1. IP-G21 Description 2.1.1 About IP-G21 Unit 2.1.2 Parts and Functions 2.1.3 About main menu 2.1.4 Specification 2.2. DT-IPC Introduction 2.2.1 About DT-IPC Unit 2.2.2 Parts and Functions 2.2.3 Specifiction 2.2.4 Installation Setup Instructions 2.2.5 Wiring Diagram 2.2.
§§ 2.1 IP-G21 Description 2.1.1 About IP-G21 Unit The IP-G21 Guard Unit is designed as a dedicated switchboard to support IP network system, which can be used for 2-wire or CAT5 network system. Guard Unit is an essential part in IP system, it makes possible to manage calls from(to) Common Door Station or Door Station, and Indoor Monitor. Additionally, IP-G21 has other functions, such as alarm receiver, depends on system configuration. Max. 8 IP-G21 can be connected in system.
a.Manual Monitor: Press Manual Monitor icon on main menu page,a digital keypad will be shown on screen. Input the address by pressing the keypad,then press unlock or monitor icon,you can release the door or see the conditions of common door staion or door staion. Otherwise,you can monitor or release the door for common door station or door station by namelist,please press List icon to show the name list.
b.Intercom: The Guard Station can make a call to common door station,door station and indoor monitor,just input the address by pressing keypad,then press Dial icon to activate the intercom call.(the intercom call also can be activated by namelist,just press List icon to show name list ) c.Event: Press Event icon on main menu page ,total 8 items on this page. It's available for G21 to search alarm and calling information, and can directly clear all events on G21.just press Event Clear icon.
The G21 supports picture memory function,and the pictures can be playbacked on G21,at this page ,press Memory Playback icon ,each memo can display 4 pictures named by date, and the pictures can be copied to SD card,just press Memory to SD icon. 2012-01-10 004 2012-01-10 003 2012-01-10 002 2012-01-10 001 d.User Setup: User setup includes date and time set,ring tone set,monitor time set,password set,call divert set,menu upgrate,and system tools set.These setting items can be modified at any time.
e.Shortup: This section offers more convenient and effective methods for guard person to make a call,just pressing the icon,calling is activated immediately. f.Service: 2.1.
§§ 2.2 DT-IPC Introduction 2.2.1 About DT-IPC Unit The DT-TPC unit is designed for DT 2-wire system to support IP networking. It is a network gateway which is an essential node in IP network. 60 mm DT-IPC is capable of connecting block system and Common Door Station, intercom point. It makes the door intercom can be available in a PC as well as from the Indoor station or Guard Unit. Answering calls and releasing doors, or monitoring entrances are also available. Max. 239 DT-IPC can be connected in system.
Terminal description: Item Status indicator Name LED202 Description After power on for 10s,it will flicker Always on while working LED203 DIP switches Network Signal Input SW201 Refer to DIP switches setting in followings S201 Refer to DIP switches setting in followings J701 RJ45 connection, connected to network.
2.2.4 Installation Setup Instructions a) DIP switches settings: ON(1) ON OFF(0) ON = = DIP Switch Status(Defaults are OFF) S201 switches settings: Total 6 bits switches.Bit-6 is used to set the video impedance matches. Bit state Setting Bit state Set to high impedance ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 Setting Match video impedance Functions of bit1 to bit 5 are reserved.
2.2.
C Block D Block SOS station Guard Unit IP-2 wire system technical guide -26-
2.2.6 IP Address Setup For constructing a DEDICATED LAN for IP system, all network devices must be specified different IP Address. * Network device model includes DT-IPC, CM-IPC, IP-G21 and PC Station.We will just state device short for network device in the following statement. * All network device can be detected by IP8210 config and IP-Device, but only DT-IPC, CM-IPC & IP-G21 can be set by the two softwares. PC Station is set by Windows IP setup 1.
Steps for IP Setup a.Set PC IP address (Assume that IP of PC is set to 192.168.0. 125) * See the notification area in the bottom right corner of windows desktop * Press icon in the notification area. It will pop up a window for selecting network. Click Open Network and Sharing Center item. * Select Local Network in the pop-up window.
* Press Properties button in the Local Network Status window * Select Internet Protocol Version 4(TCP/IPv4) item in the Networking tab of Local Network Properties window * Select Use the following IP address option in the General tab of Inter Protocol Version 4(TCP/ IPv4) Properties window -29- IP-2 wire system technical guide
* Input IP address, Subnet mask and Default gateway as following picture shows, then press OK button to finish setup b. Connect device to PC directly or the network c.
d. Press Search… button to search the device. You can press Stop button to end the search after the device has been detected. Just like the following picture shows e.
f. It will pop up a window for IP address config. Modify IP address, and then press OK button to confirm. Its Mac address will be automatically modified simultaneously. g. If setup is successful, it will pop up a window to inform you.
3. IP Adress Setup by IP Device Software An IP setup tool has been inserted in IP Device software. The function is the same to IP8210 config software. Steps for IP Setup a) Install PC Station package software. And IP Device software shortcut will be created automatically in the desktop. b) Set PC Station IP Assume using the following IP address : IP address: 192.168.0.246 Subnet mask: 255.255.255.0 Default gateway: 192.168.0.1 Note that IP address range of PC station must be from 192.168.X.241 to 192.168.X.
d) Start IP Device software e) Click right mouse button on Benchmark Project, then select IP Node Config in the pop-up menu f) In IP Node Config page, press Scan & Check button IP-2 wire system technical guide -34-
g) Then it will pop up a window to show devices that are detected. Assume that 192.168.0.2 is the device that is supposed to be set to 192.168.0.93.
h) Double click 192.168.0.2, then a window pops up for modifying IP, input 93 then Mac address will be automatically modified. Press OK button to confirm modification. i) A window will be pop up to inform you if config succeed, just like the following picture shows.
4. Find Specific Network Device in IP System In the IP system, if you want to check device IP or find specific network device, you can operate it as follows, take DT-IPC as example. a. Check Device IP 1) Press K201 button in DT-IPC 2) Device info will be shown in IP device software in 2s.
b. Find Specific Network Device If you don’t know the related device of specific IP address, you can find out the relationship by tip device function in IP device software. 1) Select one IP device you want to check, click right mouse button on it, select Tip Device in the pop-up menu. 2) Then LED202(red)&LED203(blue) of the related DT-IPC will blink 8 times simultaneously.
5. Check Network Device Online The status of devices is unchecked after configurated. The following are two methods for checking network device online 1) Press Refresh Online button on the left-bottom corner in main page of IP device software. 2) Click right mouse button on Benchmark Project, then select Check Network Device Online in the pop-up menu. As you see, D Block, Guard Station 2 & Guard Station 1 are offline. Network Camera is online, but device model doesn’t correspond with the connected device.
Chapter 3 Software Introduction 3.1. Software Installation 3.2. IP-Device Introduction 3.3. IP-Agent Introduction 3.3. 1 Overview 3.3. 2 IP-Agent Description 3.3. 3 Monitor Viewer 3.3. 4 Record Viewer 3.3. 5 Capture Viewer 3.3.
§§ 3.1 Software Installation 1. Double Click Setup.exe. Start to install PC Station 2. Select language, then click Next.
3. Click Next 4. Select folder for installation, then click next 5. Click Install button to begin the installation, then waiting till installation finishes.
6.
ID: Device Password: 123456 Server Name: Machine Name + ‘\K2012’ Database Name: K2012 IP-2 wire system technical guide -43-
§§ 3.2. IP-Device Introduction IP-Device is used to construct a new project and save project info to a database for IPAgent whose info is based on the database. Recommended Configuration Route: Project Property -> IP Node Config -> Block Config -> Guard Centre Priority Setting -> Call Table for Blocks -> Call Table for Common Entrance -> Parameter Management for Blocks and Common Entrance IP Device Interface Instructions 1.
It will pop up a window for setting project property. IP Seg: Select a IP Segment for the new project. We will take 192.168.0.X as an example in this manual* Project Name: Name the new project Project Description: Can input some info about project Project Mark: Can input some info about project Insert time line: Insert created time in Project Mark frame. See the picture above, Benchmark Project is assumed a 2 wire/IP system.
2.IP Node Config Click the right mouse button on Benchmark Project, then select IP Node Config. Select IP nodes which will be adopted in this project, select its model and name the device. IP Nodes Description IP Nodes Description 192.168.0.2 to 192.168.0.240 Door Station/Common Door Station/ Camera 192.168.0.241 to 192.168.0.246 PC Station( IP-Agent ) 192.168.0.247 to 192.168.0.
For example, in Benchmark Project, see the table, IP Nodes can be configured like the following picture IP Device 192.168.0.20 Camera 192.168.0.20 to 192.168.0.24 Door Station 192.168.0.25 to 192.168.0.26 192.168.0.254 and 192.168.0.253 192.168.0.243 and 192.168.0.244 Common Door Station Guard Unit( IP-G21 ) PC Station( IP-Agent ) IP Node Config: If all the device has been installed in the project, you can click the Scan & Check button to search if the selected IP Nodes are online.
If you want to check if the devices are online, you can press Refresh Online button or click right mouse button on Benchmark Project then select Check Network Device Online. See the following picture, Means device offline, and means PC is online, but IP-Agent isn’t opened. indicates the model of IP Node is wrong selected, or wrong DIP switch setting of IPC.
3. Block Config Double Click A Block, you will find no door stations and monitors there. Door stations and monitors must be configured. Take Benchmark Project as an example. There are 2 DT592 and 4 monitors in A blocks. User Codes of monitors are 00, 01, 02 and 03 respectively.
Monitor Config: Click the right mouse button on A Block -> Select Monitor Config on the pop-up window -> Config just like the following picture -> Click Save button to confirm -> Software will check if the monitors are online automatically.
Note that 0032(User code) is equal to 0000 when door station is DT592 or DT596 IP-2 wire system technical guide -51-
DS and Monitors Config of other blocks in Benchmark Project can use the same method to config. 4. Guard Centre Priority Setting This setting is configured for guard centre( PC Station and Guard Unit) priority.
See the following picture, there are 8 position for calling transfer. For example, when one door station or monitor call Guard Centre, it will call GL 1 firstly, if GL 1 is busy or offline, the calling will be diverted to GL2, if GL2 is busy or offline, the calling will be diverted to GL 3… Repeat this till divert the calling to the last Guard Centre. Press the Write to all device button to download the info to all devices connected to the network, and info will be saved to database at the same time.
5. Call Table For Blocks For DT-IPC of blocks, there is 2 call tables for calling guard station: Button Call Table and Call Priority. The route for Call Table(Take B Block as an example): Click right mouse button on B Block -> Management -> Call Table, see the following picture, both of them have 2 buttons, View & Edit and View On Device. Press View & Edit, you can view the table in the database and edit, then can download the edited table to the corresponding DT-IPC.
Pick one Guard Centre for 32, then press ok button IP-2 wire system technical guide -55-
If you want to cancel the mapping between call No. and Guard Centre, press the Delete Guard Centre button Delete Guard Centre Repeat the similar operation to fulfill the mapping between call No. and Guard Centre.
Press the Write to Device button to save and download to the corresponding DT-IPC after finish. The below table is the description for the mapping Index Device Name Direct Button Door Station(DMR11/D8 + EP24) 28 Guard Station 4 (192.168.0.244) Specified Button. 28th button by default Guard Station 2 (192.168.0.253) Guard Station 3 (192.168.0.243) Guard Station 1 (192.168.0.254) Specified Button. 29th button by default Specified Button. 30th button by default Specified Button.
Note that: for the above example, press 32 to call Default GL, calling can be diverted when destination is busy or offline. The called Guard Centres and diverting order depend on the info that had been stored in the corresponding DT-IPC. Press View on Device of Call Priority to view the Guard Centre Priority. The operation for Guard Centre Priority will be introduced in the next part.
If you don’t want to use the Default setting, deselect the Use Project Default item, and then edit the private calling diverting order for the corresponding DT-IPC. Press write To Device button to download the info to the corresponding DT-IPC. Click the Download All button to download Button Call Table, IP Call Table and Call Priority at one time.
6. Call Table for Digital Input Common Entrance Panel(DMR18) 192.168.0.25 had been configurated to be CDS(Common Door Station) in IP Node Config Chapter. Assume that DMR18 had been connected to this DT-IPC. For Digital Input Common Door Station(DMR18), only Common Call Table and Call Priority should be cared about. For Call Priority setting is similar to call Priority section in Call Table for Blocks chapter, this chapter just focus on Common Call Table.
Mapping Rule * Using Default Rule to call Guard Unit and monitors. For example, press 254-01 to call Guard Station 1, press 243-01 to call Guard Station 3, press 024-15 to call the monitor whose user code is 15 in D block. * New rule for Mapping between Common Entrance and monitors As the above CDS Input, for example, press 004-07 to call the monitor whose user code is 15 in D block after the rules are download to device. 7.
Press View & Edit of Button Call Table tab to edit the calling mapping, just like the following picture.
It will pop up a window for you to pick a user.
Fulfill the call table, then press Write To Device to download the info to the corresponding DT-IPC. You can call user or Guard Center by the corresponding button, for example, press 32nd button to call Default Guard Center, press 20th button to call the monitor whose user code is 15 in D block. 8. Parameter Management for Blocks and Common Door Station Because the item meanings of parameter management for blocks and common door station are the same.
Button Description: Read From Device: Read all the info stored in the device Write To Device: Write all the info to the device Reset To Default: Reset all the info in the database to Default(Note that the operation is for database in PC, if you want to reset the device info, press Reset To Default and then press Write To Device) Import: Import a parameter file that has been saved before to reset the info. Export: Export a parameter file to backup the current info.
highest one. GL Call IM: To set Priority for Guard Center calling indoor monitor. CDS Call IM: To set Priority for Common Door Station call indoor monitor. DS Call IM: To Set Priority for door station call indoor monitor b. 8210 Control IP-8210 Reset Check Number: If DT-IPC had been detected offline N times, start powerdown mode. To set the N value. IP-8210 Power Cut Time: Timing for power-down when reset DT-IPC IP-8210 Reset Count: Counting for DT8210 resets c.
DIP Status The DIP Status page is used to show the DIP status of SW201 in DT-IPC. DIP OFF ON 1 Reserved Reserved 2 Other DS DT591/DT592 3 4 Local Guard Center Door Station Network Guard Center Common Door Station ON 1 2 3 4 Dip Status page Description Guard Center: To show the 3rd DIP status of SW201, Local Guard Center or Network Guard Center.
§§ 3.3. IP-Agent Introduction 3.3.1 Overview What's IP-Agent IP-Agent is one part of PC Station. It’s a guard center that enables you communicate with user, entrance of blocks, common entrances and other guard centers in one residential area via IP network. Unlock door when talking with entrances or monitoring.
-Capture picture of DS & CDS when monitoring, calling and talking manually. -Record video of DS & CDS when monitoring calling and talking manually - Record video automatically when incoming calling from DS & CDS, optional -Transmit Video of related camera to monitor when calling user, optional -Monitor up to 12 devices(CD/CDS) simultaneously -Monitoring can be activated automatically when IP-Agent gets start. -Support two kind of pixel aspect ratios formats, 4:3 and 16:9 -Support full screen mode.
Login To Access IP-Agent, you must log in with a registered account at first 1. On your desktop, double click the IP-Agent icon,the login dialog should appear. 2. Provide the user ID and password Default ID: device Default Password: 123456 3. Provide the Server name and Database Name Server name: machine name + ‘\K2012’ Database Name: K2012 * The default password can be exposed to a hacking thread so it is recommended to change the password by IP-Admin software after installing the product.
IP-Agent at a Glance 3 1 4 5 6 7 2 Item Name Description 1 S/W Title Bar Display the name of the software 2 3 4 ID Monitor Record Shows the user ID Launches the Monitor Viewer. Launches the Record Viewer 5 Capture Launches the Capture Viewer 6 Setup Open the setup page 7 Exit Terminates the application 3.3.3 Monitor Viewer From the top right corner of the IP-Agent main screen, click the [Monitor] tab.
Name and Fuction of each Item in Monitor Viewer Item Name Description 1 Device List Consists of 4 parts: GL&PC, DS&CDS, Monitor&Camera 2 3 4 5 6 7 8 9 10 Call List Alarm Unlock 1 * Unlock 2 * Capture Record Digital Keypad Exit Maximum Call info record Alarm and events record Unlock the first latch of the entrance Unlock the second latch of the entrance Capture a picture of the selected video window Performs/Stop Recording the selected video window Open digital keypad for operation Exit monitoring M
*Note that Unlock 1 and Unlock 2 buttons can unlock the 1st and 2nd latches respectively if door station model can connect two latches.
Item Name Description 1 Capture Capture a picture of the video window 2 3 4 Record Unlock 1 Unlock 2 Speaker Volume Mic Volume Exit Maximum Performs/Stop recording the video window Unlock the first latch of the entrance Unlock the second latch of the entrance Adjust speaker volume via up and down button Adjust mic volume via up and down button Exit the communication window Maximize the video window 5 6 7 -74- IP-2 wire system technical guide
Device List Device List consists of 4 parts, including GL & PC, DS & CDS, Monitor and Camera. After device configuration operation in IP Device software, all the devices that have been configurated in IP Device will shown in the Device List. Icons & Description: 1. : Device Online 2. : Device Offline 3. : PC Online, but IP-Agent doesn’t open 4. : Invalid Model 5. : Call 6. : Monitor a. GL & PC GL & PC is a list of Guard Centers, including Guard Station and IP-Agent.
Call Failure: * Detail refers to trouble shooting * Incoming Call 1) Press Accept to entry talking status, else press Refuse to deny the calling 2) Talking established after accept the calling, you can press Handup button to end the conversation b. DS & CDS All the door stations & common door stations are listed in this frame. * Search one DS/CDS You can input full or part of a device name to search one DS or CDS in the Search input box.
* Incomcing Call 1) Press Accept to entry talking status, else press Refuse to deny the calling 2) Talking established after accept the calling, you can press Handup button to end the conversation * Monitoring DS/CDS Press button to monitor the related DS or CDS. The video will be shown in the focused monitor window.
All the monitors of one selected building are listed in this frame. c.
* Call when IP Camera connected If IP Camera function is activated by setting*, video of IP Camera will be transmitted to IPAgent and the called monitor simultaneously.
d. Camera You can connect one camera to IP Network via CM-IPC. Press to view the network camera Call List Click the Call List tab to unfold the lists. Call List is a record that includes call destination/call source, date, time and length of time * Icons & Description of Sub Lists 1. (All Call): All call info including outgoing calls, incoming call, missed calls 2. (Calls): Outgoing call info 3. (Incomings): Incoming call info 4.
3.3.4 Record Viewer From the top right corner of the IP-Agent main screen, click the [Record] tab.
Name and Function of each Item in the Record Window Item Name Description 1 Device Name Displays the recorded device name 2 Record Time Displays the time when the video/audio was recorded Record List Record operation will be activated in the following cases: 1.Incoming calls from DS/CDS or monitor and respond the calls 2.Call DS/CDS or monitor and Auto Recording On Call function has been activated by setting*1 3.
Icons & Description 1. (All Record): All record including audio record, video record and talk record 2. (Audio Record): Audio record for conversation between IP-Agent and monitor(based on setting), no video 3. (Video Record): Video record for DS/CDS when monitoring(based on setting) , no audio 4. (Talk Record): Talk record for conversation with video 5. (Record Filter): Filter record by specific time and address Double click to select one record to display in the video screen.
3.3.
To View Big Picture 1. Select one picture in the captured picture list. 2. Double click the selected picture, then video screen will turn to big picture mode from browse mode.
3.3.6 Setting From the top right corner of the IP-Agent main screen, click the page. button to entry setting a.
Record Record Path: Select a path to save all record documents Auto Recording On Call: Activate auto recording when IP-Agent call devices Auto Recording On Monitoring: Activate auto recording when monitoring devices Language Language: English or Chinese(Simplified) optional Video Video Type: PAL or NTSC optional Maintain the aspect ratio: Maintain the aspect ratio or not Timer Max call time: To set max call waiting time Max monitor time: To set max monitor time for monitoring b.
Channel On Start : To set initial aspect ratio and split number of the video screen when IP-Agent gets start Layout: To set initial aspect ratio for video screen when IP-Agent gets start Channel Number: To set initial channel number for video screen when IP-Agent gets start Enable Max Channel: Deselect the option to disable 9 and 12 channel selection in the main frame Monitor On Start: To select specific DS/CDS to monitor automatically when IP-Agent gets start View: Device list display setting Show IP: Dese
Handset: Add one handset to IP-Agent Use handset: Enable a handset Com Port: Select related com port for the connected handset Ring Sound: Select a Ring Tone for handset Ring Volume: Adjust Ring Volume for handset IP-2 wire system technical guide -89-
Appendix 1 Prepare a IP network in DT system All the setup is set in IP-Device software beside door station ID code setting, Monitor user code setting and DIP setting of DT-IPC. 1. Project Property Project Name: TEST001 Project Descriptions: Totally 4 blocks, 2 Common Entrances, 2 G3LV, 2 IP-Agent Project Remark: 2 wire system IP seg: 192.168.0.X 2. IP Node Config Config the IP Node which will be used in this project IP Enable Model Device Name 192.168.0.
3. Guard Centre Priority Default GL Input 00 The Order of Default GL call transfer GL1 254(192.168.0.254) GL2 253(192.168.0.253) GL3 243(192.168.0.243) GL4 244(192.168.0.244) GL5 none GL6 none GL7 none GL8 none 4.
IP Address Model Device Name CDS Input 192.168.0.21 1 DT59X A Block-01(DT592) 192.168.0.21 192.168.0.21 192.168.0.21 192.168.0.21 2 0001 0002 0003 DT59X Monitor(DT) Monitor(DT) Monitor(DT) A Block-02(DT592) A Block-0001(Slave) A Block-0002(Slave) A Block-0003(Slave) 001-01 001-02 001-03 192.168.0.21 0032 Monitor(DT) A Block-00 or 32(Master) 001-00 192.168.0.22 1 DMR18 B Block-01 192.168.0.22 2 DMR18 B Block-02 192.168.0.22 0001 Monitor(DT) B Block-0001 002-01 192.168.0.
IP Address Model Device Name CDS Input 192.168.0.24 0012 Monitor(DT) D Block-0012 004-12 192.168.0.24 192.168.0.24 192.168.0.24 192.168.0.24 0013 0014 0015 0016 Monitor(DT) Monitor(DT) Monitor(DT) Monitor(DT) D Block-0013 D Block-0014 D Block-0015 D Block-0016 004-13 004-14 004-15 004-16 192.168.0.24 0017 Monitor(DT) D Block-0017 004-17 192.168.0.24 0018 Monitor(DT) D Block-0018 004-18 192.168.0.24 0019 Monitor(DT) D Block-0019 004-19 192.168.0.
A Block(192.168.0.21) General Description: 1) 2DS and 4 IM, use DT592 model 2) 1st button in DT592 call all IM. 2nd button call default Guard Unit(Default GL). 3) User Namelist in IM to call Guard Station IM Description: 1) Totally 4 IM in this block whose user codes are from 00 to 03 2) [16] in Namelist to call Default GL, [17] to call Guard Station 2(192.168.0.253), [18] to call Guard Station 3(192.168.0.
Edit Button Call Map table: Index Device Name IP 32 Default GL 192.168.0.254 31 30 Guard Station 2(G3LV) Guard Station 3(IP-Agent) 192.168.0.253 192.168.0.243 Adress FFFF Press Write to Device to download the setup to DT-IPC(192.168.0.22) after finished C Block(192.168.0.23) General Description: 4 DS and 8 IM, use DMR11 and DT598 model IM Description: 1) User codes of IM are from 01 to 08 2) [09] in Namelist to call Default GL, [10] to call Guard Station 2(192.168.0.
DS Description: 1) 1 DMR11/8 + EP24, ID code: 00 2)Press 32 to call Default GL, 31 to call Guard Station 2(192.168.0.253), 30 to call Guard Station 3(192.168.0.243) Call Table Setup: A Block -> right Click then select Management -> Select Call Table -> Select Button Call Table -> Select View & Edit Edit Button Call Map table: Index Device Name IP 32 Default GL 192.168.0.254 31 30 Guard Station 2(G3LV) Guard Station 3(IP-Agent) 192.168.0.253 192.168.0.
IP-2 wire system technical guide Com m on Entrance 1 1 D S(D M R18) G uard Center 2 PC Station 2 G uard Station 2 D S(D M R18) 1 U sers (4*IM ) 2 D S(D T592) 1 U sers (4*IM ) N etw ork Cam eras 4* Cam eras in Q uad Block B Block A Block C 3 D S(D M R11) 1 D CU (Cam eras) 8 U sers (8*IM ) Com m on Entrance 2 1 D S(D M R11) 1 D S(D M R11) 24 U sers (24*IM ) Block D DT Network Benchmark Platform Diagram -97-
Appendix 2 System Design Process 1. Analyze Project Requirement 2. Count Project Points 3. Select Device Model & Make Device List 4. Draw System Topology Diagram 5. Make Project Technical Solution Document for Business There are 3 buildings including one villa, two apartments. And there are one common entrance, 2 Switchboard including 1 PC station & 1 guard station in these residential complexes. In this application, a door entry system with the features below is required: 1.
2. Count Project Points All the above requirement can be met by 2-Easy intercom system. Building No. of No. of floors flats on Total flats for 1 building each floor IM Distributor Power Gateway DS supply A Block / / 1 4 1 1 1 1 B Block C Block Total 8 6 2 4 16 24 41 16 24 44 4 7 12 1 1 3 1 1 3 1 2 4 3.
System Wires Series Name 1 Wire for Apartment riser connection 2 Wire for Network CAT5 Connection -100- Model Twisted Cable Qty Unit / Meter / Meter IP-2 wire system technical guide Remark Using twisted cable to connect riser devices in apartments. 2*1.0mm2 or 2*1.
4. System Topology Diagram Twisted Cable 2*1.
SY A 2E