Installation Guide

Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1078258-R02
17/03/2020
1078258-R02
4
General information about installation
The worktop must be flat so that it is sufficiently sealed against the ingress of liquids.
In order to guarantee good ventilation, a space of at least 10mm in height is necessary beneath the appliance.
Overlying installation
The layout of the hob to be fitted may differ from the hob illustrated!
490±1
≥50
≥50
A
680±1
60
0
=
=
=
=
Ra
571
50
1
Y
Y
Ri
H
490±1
56
0±1
50
5
0
A
60
0
Ra
501
Ri
H
691
Y
Y
≥10 *
B
Y – Y
H
Drawer/cabinet
CTI4T74MMSOLDCTI4T64MMSOLD
Cable length 1.7 mCable length 1.7 m
* The required clearance must be observed!
Type A Depends on producer B H Corner radius Ra/Ri
CTI4T64MMSOLD, CTI4T74MMSOLD ≥20mm ≥60mm 50mm 5/1.5mm
A Worktop depth
B Required clearance for ventilation and service replacement over the entire cut-out area.
H Dimension from the top of the work surface to the underside of the hob (ventilation opening)
Ri Corner radii of appliance Ra Outer corner radii of cut-out
Installation
1. Create the mounting cut-out accurately.
2. Carefully place the appliance in the mounting cut-out and push against the work surface until flat.