Installation Guide

Installation instructions
CTI4T64/74
CookTopInduction V4000
Glass ceramic hob
1078258-R02
17/03/2020
1078258-R02
5
Flush installation
The layout of the hob to be fitted may differ from the hob illustrated!
507±
1
5
7
7±1
≥41.5
≥41.5
A
600
571
50
1
Y
Y
X
X
Ri
Z
H
501
691
Y
Y
A
5
07±1
≥41.5
≥41.
5
6
0
0
Z
697
±1
X
X
Ri
H
CTI4T64MMSOLD CTI4T74MMSOLD
Cable length 1.7 mCable length 1.7 m
H
≥10 *
Y – Y
B
Drawer/cabinet
Side panel
B
H
≥10 *
X – X
600
C
D
Ra
R0–5
8.5
0
-1
8.5
0
-0.5
8.5
8.5
+1
0
+1
0
Detail Z
Steel angle mounted
with adhesive or screws
* The required clearance for ventilation must be observed!
Type A Depends on producer B C/D H Corner radius Ra/Ri
CTI4T64MMSOLD ≥20mm ≥75mm 560/490 51.7mm 5/1.5mm
CTI4T74MMSOLD 680/490
A Worktop depth
B Required clearance for ventilation and service replacement over the entire cut-out area.
H Dimension from the top of the work surface to the underside of the hob (ventilation opening)
Ri Corner radii of appliance Ra Outer corner radii of cut-out
Installation
1. Create an accurate installation cut-out.
The mounting surface can be reamed out or created by installing wood/stone supports or using the steel angle set (see Accessor-
ies).
Access to the appliance from below via the entire cut-out area must be guaranteed. For servicing purposes, the induction gen-
erator can be removed from below with the mounting plate. It must be possible to unscrew the contact-proof covers from be-
low.
2. Prepare the cut-out and appliance in accordance with the specifications in the enclosed cementing-in instructions.
3. Carefully cement the appliance in and leave the silicone sealant to dry for at least 24 hours.
4. Connect to the electrical mains connection before inserting the appliance, if necessary.