Electrical connection
Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
Refer to the identification plate for information on the required mains voltage and current type.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.
If the hobs are used at an altitude of over 2,000metres,a reduced performance must be expected.
The appliance is equipped with a connection cable which must be connected to an on-site junction box.
Installation pipe Distribution boxClamp
brown
blue
yellow/green
grey
blue
yellow/green
brown
L3
L1
N
N
L1
PE/
PE/
black
L2
400 V 3N~ / 16 A
230 V~ / 48 A
blue
yellow/green
brown
L1
N
PE/
black
L2
400 V 2N~ / 16 A
3106200.../3106203.../3106260.../3106266...
3113400001–3113400003
3106261.../3106265.../3106267...
3113400004
E35/U0 error message
Incorrect connection:
Pole conductor connected to connection terminal for neutral conductor.
Quickly disconnect the appliance from the mains!
General information about installation
The distance from the appliance cut-out to flammable walls (left, right and rear) must be ≥50mm. Parts such as side
walls and reinforcing strips which protrude into the installation space under the cooking zone must be made of non-
combustible materials.
It is recommended that a distance of 20mm be maintained between the underside of the appliance tray and any part
of the cabinet beneath that is made of combustible material. If a drawer is installed directly underneath – and if the
tray can be reached from below without the aid of tools – touch protection must be used. The ventilation protective
plate set (see Accessories) is recommended for this purpose.
The worktop must be flat so that it is sufficiently sealed against the ingress of liquids.
In order to guarantee good ventilation, a space of at least 10mm in height is necessary beneath the appliance.