Operation Manual

Settings
16
Key to parameters
Model 245 and model 246 (appliance 1)
Parameter Function Description
Operating mode
appliance 1
For setting the operating mode to
time-dependent (0)
or usage-dependent (1) operation
Unit for
time-dependent operation
appliance 1
Defines the length of time (e.g. 1 hour)
during which the tariff in P13 is valid.
Tariff for
time-dependent operation
appliance 1
Charge for (e.g. 1 hour) washing/
drying according to time defined in P12.
Unit for
usage-dependent operation ap-
pliance 1
Defines the length of time (e.g. 1 hour)
during which the tariff in P15 is valid.
Tariff for
usage-dependent operation
appliance 1
Charge for (e.g. 1 hour) washing/
drying according to time defined in P14.
Current response threshold
appliance 1
Changing the current response threshold determines the level of
power consumption from which charging begins.
Power display
appliance 1
Shows actual power consumption. This parameter cannot be
changed. If a value greater than 1.0 A is measured,
is displayed.
Shut-off delay time
appliance 1
Depending on the washing machine or tumble dryer connected,
there are pauses during a programme sequence (gaps in the power
being drawn). As soon as there is a gap that is greater than the set
shut-off delay time (end of programme), charging is ended.