Installation Guide
Installation instructions
Range hood
Mode: Extraction / Recirculation
DSTS9
1011458-R02
15/03/2016
8
For flush installation:
Use cementing-in set for flush installation, art. no.
86392885.
▸ Raise the range hood.
▸ Apply sealant and allow sealant joints to dry completely.
Extraction mode
There is a danger of toxic fumes developing if the range hood is operated at the same time as an ambient
air-dependent firing system!
▸ Fasten exhaust ducting 22 to exhaust connection 23.
Flat channels and hoses are available as accessories (see
section 19.4 of the planning aid).
22
23
▪ Only use smooth pipes or flexible duct hoses made from non-flammable materials for exhaust ductwork.
▪ To achieve the greatest possible air extraction with the lowest noise levels, please note the following:
– The diameter of the exhaust duct must not be less than 150mm.
– If flat exhaust channels are used, the cross section should not be smaller than that of the exhaust air connec-
tion.
– The exhaust ducting should be as short and straight as possible.