Wet/Dry Vacuum Operator’s Manual 2.5 Gallon Model No. VOM205P FOR YOUR SAFETY Read and understand this manual before use. Keep this manual for future reference. Distributed By Cleva North America, Inc. 601 Regent Park Court Greenville, SC 29607 Replacement Filters & Accessories available at: Vacmaster.
TABLE OF CONTENTS SECTION PAGE Warranty ...................................................................................................................................... 2 Important Safety Instructions ....................................................................................................... 3 Double Insulation Instructions ..................................................................................................... 4 Extension Cords ..............................................
IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS VACUUM.Read and understand this operator’s manual and all labels on the Wet/Dry Vacuum cleaner before operating. Safety is a combination of common sense, staying alert and knowing how your vacuum works. Use this Wet/Dry Vacuum only as described in this manual. To reduce the risk of personal injury or damage to your Wet/Dry Vacuum, use only manufacturer recommended accessories.
When using as blower: • Direct air discharge only at work area. • Do not use Wet/Dry Vacuum as a sprayer. • Do not direct air at bystanders. • Keep children away when blowing. • Wear safety goggles. SAVE THESE INSTRUCTIONS DOUBLE INSULATION INSTRUCTIONS This Wet/Dry Vacuum is double-insulated, eliminating the need for a separate grounding system. Use only identical replacement parts. Read the instructions for Servicing Double-Insulated Wet/Dry Vacuum before servicing.
EXTENSION CORDS When using an extension cord with your Wet/Dry Vacuum refer to the following table to determine the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord are in good working condition. Make repairs or replacements before using the vacuum cleaner. Only use extension cords that are rated for outdoor use. 120V Ampere rating More than Not more than 0 6 6 10 10 12 12 16 Length of Extension Cord 50ft (15.24m) 100ft (30.48m) 150ft (45.72m) 25ft (7.
UNPACKING & CHECKING CARTON CONTENTS A B D F G H Remove all contents from the box. Remove the power head and take out any contents inside the collection tank. Check each item against the carton contents list. C Carton Contents List: Key Description........................... Q t y. A Vacuum Assembly....................1 B Wall Mount Bracket...................1 C Hose.........................................1 D Crevice Tool..............................1 E Utility Nozzle.............................
GENERAL ASSEMBLY INSTRUCTIONS Tools Required for Assembly: Philips Head Screwdriver Helpful Tools: Level WARNING: DO NOT PLUG THE POWER CORD INTO A POWER OUTLET. MAKE SURE THE PLUG IS DISCONNECTED BEFORE ASSEMBLING THE WET/DRY VACUUM. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE TO RAIN. 1 2 3 4 5 6 9 9 10 11 12 1 2 7 8 13 14 UNPACKING YOUR WET/DRY VACUUM & GENERAL ASSEMBLY 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2. Undo the latches (Fig. 2). 3.
. Place the power head back on the collection tank aligning the top section with the latches, and snap into place (Fig. 9 & 10). 9. Insert the larger end of the hose into the vacuum port on the collection tank and lock into place (Fig. 11). 10. Choose the desired attachment and insert onto the end of the hose (Fig. 12). For your convenience this vacuum comes with a wall mount bracket for storage. IMPORTANT! • Do not mount the bracket over 5 ft / 1.5 m from the floor.
DRY VACUUM OPERATION 2 78 3 4 5 6 8 DRY VACUUMING WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION ENTITLED “IMPORTANT SAFETY INSTRUCTIONS”. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO: COAL, MAGNESIUM, GRAIN, OR GUN POWDER.
LIQUID VACUUM OPERATION 1 2 3 4 58 6 7 LIQUID VACUUMING WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION ENTITLED “IMPORTANT SAFETY INSTRUCTIONS”. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO: COAL, MAGNESIUM, GRAIN, OR GUN POWDER.
BLOWER OPERATION 12 2 4 3 5 6 72 This Wet/Dry Vacuum has blowing capabilities. To use the blower feature follow the instructions listed. WARNING: ALWAYS WEAR SAFETY GOGGLES COMPLYING WITH ANSI Z87.1 (OR IN CANADA, CSAZ94.3) BEFORE USING BLOWER. WARNING: KEEP BYSTANDERS CLEAR FROM BLOWING DEBRIS. WARNING: WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED. 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2.
MAINTENANCE 1 2 3 4 EMPTYING THE COLLECTION TANK WARNING: ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE REMOVING THE POWER HEAD FROM COLLECTION TANK. 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2. Disconnect the hose from the vacuum (Fig. 2). 3. Undo the latches and remove the power head from the collection tank (Fig. 3). Place power head on a soft, clean surface upside down. 4.
INSTALLING & CLEANING REUSABLE CLOTH FILTER 1 2 3 4 5 INSTALLING REUSABLE CLOTH FILTER 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2. Remove the power head and place in an upside down position. 3. Install the reusable cloth filter over the filter cage making sure the cage is completely covered (Fig. 2 & 3). 4. Place the power head back onto the collection tank. REMOVING & CLEANING REUSABLE CLOTH FILTER 1.
TROUBLESHOOTING WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE TROUBLESHOOTING. PROBLEM POSSIBLE CAUSE No power supply. The wet/dry vacuum will not operate. The dust comes out from the motor cover. Reduced efficiency and motor/speed vibration. SOLUTION Check the power supply, cord, breakers, and fuses. Unplug and check the power cord. If damaged, have it repaired by a professional. Faulty power cord. Collection tank is full. Empty the collection tank. Switch in the wrong position.
EXPLODED VIEW 9 1 10 2 11 3 6 4 12 7 5 8 15 13
PARTS LIST Part 1 2 3 4 5 6 7 8 9 10 11 12 13 Part Number 551012101 551012115 551012116 551012104 551012107 551098111 551012109 551004113 551009111 551012110 551012108 Description Handle Power Head Float Filter Cage Collection Tank Vacuum Port Wall Mount Hook Assembly Wall Mount Bracket Assembly Crevice Tool Utility Nozzle Foam Wet Filter Reusable Cloth Filter Hose 16 Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1