emission condenser Peltronic Manual
Table Of Contents
- Part I
- Reset / Language selection
- Safety information!
- Technical data
- Use and operation
- Installing a pump in a vacuum system
- Notes regarding the (dry) ice condenser
- Notes concerning the operation of the inlet condenser IK
- Notes concerning the operation of the Peltronic emission condenser
- Notes concerning the operation of pumping units with silencer
- During operation
- Important notes regarding the use of gas ballast
- Important notes concerning the operation of the exhaust waste vapor condenser
- Shutdown & storage
- CVC 3000 Vacuum controller
- Menu guide
- Pump down function
- Vac Control function
- Auto mode
- Program function
- VACUULAN function
- Application examples
- Configuration
- Part II
- Readjustment of CVC 3000
- Calibration in the factory
- Cleaning the pressure transducer
- Interface parameters
- Accessories
- Troubleshooting
- Replacing diaphragms and valves
- Cleaning and inspecting the pump heads
- Disassembling the housing cover at the side of the emission condenser
- Replacing the diaphragm
- Assembling the housing cover at the side of the emission condenser
- Disassembling the housing cover at the side of the ON/OFF switch
- Assembling the housing cover at the side of the ON/OFF switch
- Assembling the fittings
- Cleaning and replacing components
- Notes on return to the factory
- Warranty
- Health and safety clearance form
- EC Declaration of Conformity of the Machinery
page 46 of 120
• Ensure that the coolant outlet tubing at both con-
densers is always unobstructed and that it cannot get
blocked.
• Water pressure shock at the condensers may cause
breakage of the condenser coil!
Notes concerning the operation of the Peltronic emis-
sion condenser
Read the manual of the Peltronic emission condenser and
observe the instructions contained in that manual!
Assembling the Peltronic emission condenser:
➨ Assemble the Peltronic emission condenser
with two attachment screws (Phillips screw-
driver size 2) to the pumping unit (a).
➨ Assemble the hose connection between
pump outlet and condenser inlet (b).
➨ Slip connecting tube onto hose connection
of the Peltronic emission condenser. Se-
cure with hose clip.
➨ Connect the VACUU•BUS cable from the
CVC 3000 controller to the Peltronic emis-
sion condenser (c).
Notes concerning the operation of pumping units with
silencer
Attention: Dust-laden gases, deposits and condensed
solvent vapor can restrict air ow out the silencer. The re-
sultant back pressure can lead to damage of pump bear-
ings, diaphragms, and valves. Under those conditions, a
silencer must not be used.
NOTICE
(a)
(b)
(c)
NOTICE