Operating Owner's manual

Overview
Location and Function of Parts
GB
18
Location and Function
of Parts
Camera
Front
A Lens
This is a 14-magnification optical zoom lens.
Note
Do not touch the part around the lens and ring
outside the lens when energized. It may cause a
malfunction of the camera.
B Tally lamp
Lights in red when a VISCA tally command is
received or the camera is selected by the RM-
BR300 Remote Control Unit (not supplied)
(depending on the setting mode).
You can set the brightness of the tally lamp to
HIGH, LOW, or OFF on the menu.
C Remote sensor
This is the sensor for the supplied Remote
Commander.
When you use the upper remote sensor, set IMG
FLIP to ON in the SYSTEM menu (page 39). With
this setting the remote sensor at the rear of the
camera does not function.
D Back tally lamp
Lights in red when a VISCA tally command is
received or the camera is selected by the RM-
BR300 Remote Control Unit (not supplied)
(depending on the setting mode). The back tally
lamp does not light when TALLY MODE in the
SYSTEM menu (page 39) is set to OFF.
Flashes at intervals of about 0.7 seconds if the
rotating speed of the cooling fan motor reduces or
if the motor stops, regardless of the on/off status of
the back tally lamp.
E SONY and HD nameplates
Pull them out to turn them over and attach upside
down if required.
F POWER lamp
Lights when the camera is connected to an AC
outlet using the supplied AC power adaptor and AC
power cord.
Flashes in green when the camera receives an
operation command from the supplied Remote
Commander.
G STANDBY lamp
Lights when the camera is turned off using the
Remote Commander.
Rear
H VISCA RS-422 connector
Used for VISCA control.
For connection to the VISCA RS-422 connector,
see “Using the VISCA RS-422 Connector Plug” on
page 89.
I 75-ohm termination switch
This switch is used when an external sync signal is
used. Set it to OFF when this camera is in the
middle of a daisy-chain connection of multiple
cameras. Set it to ON when the camera is at the end
of a daisy-chain connection or when nothing is
connected to the EXT SYNC IN connector on the
camera.
J IR SELECT switch
Select the camera number when you operate
multiple cameras with the same Remote
Commander.
1
67
42
5
3
RGB/COMPONENT
VISCA RS-422
1 2 3 4 5 6 7 8 9
EXT SYNC IN
IR SELECT
75
1 2 3
OFF ON HD SD
IN VISCA RS-232 OUT SDI OUT
DC IN 12V
R
VIDEO S VIDEO
qs qd
f
g
h
k
l
;
a
j
890qa