Programmers User Manual

10
Example 3: The case using Remote Control Through Function
The details are referring to 9. Function of Remote Control.
As shown below, there are some cases that the commands and remote control through
data are generated at the same time, while remote control through function turns on the
RTS line of computer. In this case, the software of computer must correspond to full duplex.
Computer Side
RTS
TXD
(Control Command)
Remote
RXD
(Answer)
Example 4: The case using the Function of Command Termination Notification
The details are referring to 6. Function of Command Termination Notification.
As shown below, there are some cases that the commands and remote control through
data are generated at the same time, while the function of command termination notification
turns on the RTS line of computer. In this case, the software of computer must correspond to
full duplex.
Computer Side
RTS
TXD
(Control Command)
RXD
(Answer)
Execute
Command 1
Answer 1
Command 2
Remote Control ON Data Answer 2
Command 1
Answer 1
Command 2
Command Termination Notification Answer 2
ON