Programmers User Manual

114
13.52 Setting Insertion of Infrared Cut Filter Camera Control Command Type 2
Function Sets the status when infrared cut filter is inserted.
Command 00B5h
Parameter length 1 byte. Parameter
Parameter value 1h
Status None
Reference •Once this command is received, the filter insertion process and the built-in
infrared light LED OFF process are both performed simultaneously.
Format of Control Code
d0 d1 d2 d3 d4 d5 d6
Header Device Num Command Parameter End mark
FFh 30h 3Xh 00h B5h 31h EFh
Answer Format
d0 d1 d2 d3 d4 d5
Header Device Num Error Code End mark
FEh 30h 3Xh e0 e1 EFh
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example: e0 e1
No Error : 00000000B 00h 30h 30h
Busy : 00010000B 10h 31h 30h
Parameter Error : 01010000B 50h 35h 30h
Mode Error : 10010000B 90h 39h 30h
Conditions for setting of error flag
Busy •Filter insertion/removal operation is in progress.
Parameter Error •The designated parameter is an invalid value.
Mode Error •Not in status of Camera ON.
•Not in status of Host Control Mode.
•This command was received while filter was inserted.